Correct & 100% Verified Answers |Latest Version |
Already Graded A+
The purpose of this code is to establish ____ requirements to safeguard the public safety, health and
general welfare ✔Correct Answer-minimum
Where, in any specific case, different section of this code specify different materials, methods of
construction or other requirements, the most ____ shall govern ✔Correct Answer-restrictive
Where a reference code or standard includes subject matter that is within the scope of the IRC, the
provision of the ____ shall take precedence ✔Correct Answer-IRC
Compliance with the specific ____-based provisions of the International Codes inline of specific
requirements of the IRC shall be permitted as an alternative ✔Correct Answer-performance
An alternative material or method shall be approved where the proposed design is ____ and
complies with the ____ of the code ✔Correct Answer-satisfactory / intent
A permit is not required for one-story detached accessory structure, provided that the floor area
does not exceed ____ square feet ✔Correct Answer-200 sqft
Fences that are ____ feet or less in height do not require permits ✔Correct Answer-7'
A permit is not required for the replacement of branch circuit overcurrent devices (breakers) of the
required capacity in the same location (within a panel) ✔Correct Answer-True
Unattached decks not exceeding ____ square feet in area, that are not more than ____ inches above
grade, do not require a permit ✔Correct Answer-200 sqft / 30"
Where equipment replacements and repairs must be performed in an emergency situation, the
permit application shall be submitted within the ___ ___ business day ✔Correct Answer-next
working
An application for a permit for any proposed work shall be deemed to have been abandoned ____
days after the date filing ✔Correct Answer-180 days
Before issuing a permit, the building official is ____ to examine or cause to be examined buildings,
structures and sites for which an application has been filed. ✔Correct Answer-authorized
Where the building official issues a permit, the construction documents shall be approved in writing
or by a stamp that states ____ ____ ____ ____ ✔Correct Answer-Review for Code Compliance
Final inspection shall be made after the permitted work is ____ and prior to ____. ✔Correct
Answer-complete / occupancy
If located in a flood hazard area, the documentation of elevations required in Section R322.1.10 shall
be submitted to the building official prior to the ____ inspection ✔Correct Answer-final
, Signifies access that requires the removal of an access panel or similar removable obstruction.
✔Correct Answer-Access (to)
A wall supporting any vertical load in addition to its own weight is a ____-____ wall. ✔Correct
Answer-load-bearing
A finished or unfinished habitable space within an attic. ✔Correct Answer-Attic, Habitable
How water is water at a temperature greater than or equal to ____F ✔Correct Answer-110 deg F
What is the minimum uniformly distributed live load for habitable attics and attics served with fixed
stairs? ✔Correct Answer-30lbs per sqft
Wood structure panels with a minimum thickness of ____ inches and a maximum span of ____ feet
shall be permitted for opening protection in windburn debris regions. ✔Correct Answer-7/16" / 8'
The seismic provision of the IRC apply to detached one- and two-family dwellings in Seismic Design
Categories ____. ✔Correct Answer-D0, D1 and D2
For dwellings with fire sprinkler systems, exterior walls with a fire separation distance less that ____
feet shall have not less than a 1-Hour fire resistance rating with exposure from the outside
✔Correct Answer-3'
In a nonsprinklered townhouse building, the common wall between units hall be a minimum ____-
hour ____-____ ____ wall assembly. ✔Correct Answer-2-hour fire resistance rated
For townhouse separation, a parapet is not required where the roof sheathing is fire-retardant-
treated wood for a distance of ____ feet on each side of the wall and there are not penetration in the
roof within ____ feet of the common wall ✔Correct Answer-4' / 4'
Openings from a private garage directly into a room used for ____ ____ shall not be permitted.
✔Correct Answer-sleeping purposes
Doors between the garage and residence shall be equipped with a ____-____ ____ ✔Correct
Answer-self-closing or automatic-closing device
Garages shall be separated from residences and attics by not less than ____-inch gypsum board or
equivalent applied to the garage side. ✔Correct Answer-1/2"
Enclosed space under stairs that is accessed by a door or access panel shall have walls, under-stair
surface and any soffits protected on the enclosed side with ____-inch gypsum board ✔Correct
Answer-1/2"
Wall and ceilings finishes shall have a flame spread index of not greater than ____. ✔Correct
Answer-200
In combustible construction, fire blocking shall be provided to cut off all concealed draft opening and
to form an effective fire barrier between ____. ✔Correct Answer-stories