Verified Answers |Latest Version |Already Graded A+
A stop work order:
O shall state the conditions under which the work will be permitted to resume?
O all of these
O shall be given to the owner of the property involved, or to the agent the owner, or to the person
doing the work?
O shall be in writing ✔Correct Answer-All of these
What is the weathering probability for concrete in the State of Idaho?
O Moderate
O Severe
O Negligible
O None of these ✔Correct Answer-Severe - Chapter 3 weather chart
Interior load-bearing walls shall constructed, framed and fireblocked specified for:
A. All of these
B. Exterior walls
C. Fire rated walls
D. Non-load bearing walls ✔Correct Answer-C. Fire rated walls
Where the separation between the garage and the remaining portion of the residence is a floorceling
assembly, the walls supporting this assembly shall be protected by a minimum of______
A. None of these
B. ½ inch gypsum board
C. The same rating as the floor/ceiling assembly
D. ½ inch gypsum board or equivalent ✔Correct Answer-D. ½ inch gypsum board or equivalent
Conductors of branch circuits supplying more than one receptacle for cord- and plug-connected
portable loads shall have ampacities of not less than:
O 80 % of the rating of the branch circuit
O The rating of the branch circuit
O 125 rating of the branch circuit
O None of these ✔Correct Answer-The rating of the branch circuit - E3701.4 branch circuits with
more than one receptacle - 2015 IRC
When something is constructed so that moisture will not enter the enclosure under specified test
conditions, it is considered
O Weather tight
O Weatherproof
O Waterproof
O Watertight ✔Correct Answer-Watertight - Chapter 35 Definition - 2015 IRC