Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ICC CALIFORNIA UST SERVICE TECHNICIAN EXAM || LATELY UPDATED 2026/2027 QUESTIONS AND 100% CORRECT ANSWERS GRADED A+|| LATEST AND COMPLETE UPDATE 2026/2027 WITH VERIFIED SOLUTIONS|| GUARANTEED PASS!!

Beoordeling
-
Verkocht
-
Pagina's
177
Cijfer
A+
Geüpload op
18-03-2026
Geschreven in
2025/2026

ICC CALIFORNIA UST SERVICE TECHNICIAN EXAM || LATELY UPDATED 2026/2027 QUESTIONS AND 100% CORRECT ANSWERS GRADED A+|| LATEST AND COMPLETE UPDATE 2026/2027 WITH VERIFIED SOLUTIONS|| GUARANTEED PASS!!

Instelling
ICC CALIFORNIA UST SERVICE TECHNICIAN
Vak
ICC CALIFORNIA UST SERVICE TECHNICIAN

Voorbeeld van de inhoud

1|Page



ICC CALIFORNIA UST SERVICE TECHNICIAN
EXAM || LATELY UPDATED 2026/2027
QUESTIONS AND 100% CORRECT ANSWERS
GRADED A+|| LATEST AND COMPLETE UPDATE
2026/2027 WITH VERIFIED SOLUTIONS||
GUARANTEED PASS!!


Which agency approves a site-specific variance which allows for an
alternative method of construction or monitoring:
a.) The Regional Water Quality Board
b.) The State Water Resources Control Board
c.) The Department of Toxic Substance Control
d.) The local agency- ANSWER: a.) The Regional Water Quality
Board CCR Title 23, Sec 2681(a)


The regulations to enforce compliance of underground storage tank
systems in the state are found in?
a.) Code of Federal Regulations, 40 CFR Part 281
b.) California Code of Regulations, Title 23, Chapter 16
c.) Code of Federal Regulations, 40 CFR Part 280
d.) California Code of Regulations, Title 23, Chapter 17- ANSWER: b.)
California Code of Regulations; Title 23, Chapter 16


By definition an "underground storage tank system" includes
a.) The tank, all connected piping and dispensers
b.) The tank, all connected piping, ancillary equipment and containment
system
c.) Only the tank

,2|Page


d.) Only tanks totally beneath the surface of the ground- ANSWER: b.)
The tank, all connected piping, ancillary equipment and containment
system


(H&SC, Sec 25281(z))


The written report submitted to the local agency after an unauthorized release
is required to include the following except:
a.) Description of actions taken to stop the release
b.) Cause of the release
c.) Method of disposal of released product
d.) Date on which the release was discovered- ANSWER: b.) Cause of the
release CCR Title 23, Sec 2652(c)


An unauthorized release which does not escape from secondary containment
only requires a record on the operator's monitoring reports provided:
A. It did not increase the hazard of fire
B. It did not cause any deterioration of the secondary containment
C. It was cleaned up within 8 hours of detection
D. All of the above- ANSWER: D. All of the
above H&SC, Sec 25294


The annual monitoring certification may be performed by:
A. A person possessing the appropriate contractors licenses
B. An individual trained and certified by the manufacturer of the
monitoring equipment
C. A designated UST operator

,3|Page


D. A person who meets the requirements of both a and b- ANSWER: D. A
person who meets the requirements of both a and b
CCR Title 23, Sec 2715(i)


When an automatic tank gauge is utilized for single-walled tank leak
detection, it shall generate a post-test hard copy data report of the
following information, except:
a.) Liquid volume
b.) Fuel depth
c.) Outside air temperature
d.) Time and date of test- ANSWER: c.) Outside air
temperature CCR Title 23, Sec 2643(b)(1)


If a UST system is utilizing an overfill alarm, the alarm must be triggered
to alert the transfer operator when the tank is no more than full
a.) 85%
b.) 95%
c.) 90%
d.) 80%- ANSWER: c.) 90%


An automatic tank gauge is utilized for leak detection of the .
a.) Tank
b.) Tank and Piping
c.) Piping
d.) Interstitial space- ANSWER: a.)
Tank CCR Title 23, Sec 2643(b)(1)

, 4|Page


After completion of enhanced leak detection (ELD) test, the ELD test
results must be submitted to the .
a.) The local agency
b.) The SWRCB
c.) Owner of the UST system
d.) To both the SWRCB and the local agency- ANSWER: d.) To both the
SWRCB and the local agency
CCR Title 23, Sec 2644.1(a)(5)


A permit to operate a UST system must have all of the following listed on
the permit, EXCEPT:
a.) The state UST identification number(s)
b.) Name of the tank manufacturer and tank capacity
c.) Permit expiration date
d.) Monitoring requirements- ANSWER: b.) Name of the tank
manufacturer and tank capacity
CCR Title 23, Sec 2712(c)


A temporary closure is appropriate for which of the following:
a.) The UST system is empty and will be removed from service indefinitely
b.) The UST system has ceased to store hazardous materials but will be
used within the next 12 consecutive months
c.) The UST system is unable to meet compliance requirements and
will be removed
d.) The UST system has been red-tagged- ANSWER: b.) The UST system
has ceased to store hazardous materials but will be used within the next 12
consecutive months
CCR Title 23, Sec 2671 & 2670

Geschreven voor

Instelling
ICC CALIFORNIA UST SERVICE TECHNICIAN
Vak
ICC CALIFORNIA UST SERVICE TECHNICIAN

Documentinformatie

Geüpload op
18 maart 2026
Aantal pagina's
177
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$16.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
AcademicACHIEVER oxford university
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
361
Lid sinds
1 jaar
Aantal volgers
19
Documenten
11197
Laatst verkocht
3 uur geleden
A+ Academic achiever

On this page, you find all documents, package deals, and flashcards offered by seller Academic achiever

3.2

71 beoordelingen

5
24
4
10
3
13
2
5
1
19

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen