What is the purpose of the F-60 Certificate of Fitness?
To qualify individuals to serve as fire guards for torch operations.
Can the F-60 Certificate of Fitness be used as a watchperson at construction
sites?
No, applicants should take the S-60 Certificate of Fitness test for that role.
What is the application fee for the F-60 Certificate of Fitness?
$25, payable online or in person.
What is the passing score required for the F-60 exam?
At least 70%.
How many multiple-choice questions are on the F-60 exam?
25 questions.
Where is the F-60 exam administered?
FDNY Headquarters, 9 MetroTech Center, Brooklyn, NY.
What should applicants do before arriving at the FDNY for the exam?
Apply and pay for the exam online.
What is the time limit for completing the F-60 exam?
38 minutes.
,What is the significance of the National Fire Protection Association (NFPA) 51B?
It regulates the duties of fire guards for performing fire watch for torch operations.
What are fire guards required to do during hot work operations?
Reduce the threat of fires.
What is the role of a fire guard for torch operations?
To monitor and ensure safety during torch operations to prevent fires.
What is a fire watch?
A designated person who monitors for fire hazards during hot work operations.
What is the requirement for fire guards at construction sites?
At least one F-60 fire guard must be present during torch operations.
What is the procedure if the computer terminal freezes during the exam?
Ask the examiner in the testing room for help.
What materials are allowed during the F-60 exam?
Only reference material provided by the FDNY.
What should you do if you do not know the answer to a question during the
exam?
You should not ask about test questions since FDNY staff cannot assist applicants.
What are the simplified online renewal instructions for the F-60 COF?
FDNY strongly recommends renewing the COF online.
What is the importance of the Fire Prevention Code?
It provides regulations and guidelines for fire safety and prevention.
What is the role of signage during hot work operations?
To inform and warn about fire hazards and safety measures.
What are gas torch operation precautions?
Safety measures to prevent accidents and fires during torch operations.
What is the purpose of a fire guard daily logbook?
To record activities and observations during hot work operations.
What is the requirement for fire extinguisher inspections?
Regular inspections to ensure they are functional and accessible.
What types of fire extinguishers are typically used?
Different types based on the class of fire they are designed to extinguish.
What should be done with combustibles during hot work?
They must be protected or removed to prevent fire hazards.
What is the role of the FDNY Business Support Team?
To assist with questions regarding the F-60 Certificate of Fitness.
What is the significance of the fire detection system?
To alert occupants of a fire and facilitate a quick response.
What is required for torch operations at construction sites?
At least one F-60 fire guard must conduct the fire watch.
Where must the Certificate of Fitness holder keep their certificate?
The certificate must be kept on their person or readily available for inspection.
Which FDNY code section pertains to welding and hot work?
FC Chapter 35.
What is the maximum capacity of LPG containers that can be stored without a
permit?
A single standard portable LPG container must not exceed 100 lbs.
, What is the maximum capacity for a CNG container without a permit?
A CNG container must not exceed 381 SCF.
What is the purpose of a site-specific FDNY permit?
It authorizes the holder to store, handle, or use flammable gases at a specific location.
What is the validity period of a permanent FDNY permit?
Permanent permits are valid for 12 months.
What is the difference between a site-specific permit and a citywide permit?
A site-specific permit is for a specific location, while a citywide permit allows operations
at multiple locations under certain conditions.
What must be done if hazardous materials exceed specified quantities?
A site-specific permit is required for each location.
What must be provided for the use of LPG/Propane on an occupied roof?
An affidavit from a licensed professional stating the roof is constructed of non-
combustible materials.
What is the requirement for a hot work program authorization?
It must be signed and issued by the responsible person and available for inspection.
What is the maximum number of 20 lbs LPG containers that require a permit?
Three 20 lbs LPG containers require a permit.
What happens if the duration of hazardous material activity exceeds 30 days?
A site-specific permit is required.
What is the purpose of the hot work authorization permit?
It is required for any project involving hot work operations.
What is the maximum amount of gasoline that can be temporarily stored without
a permit?
5 gallons of gasoline.
What must be done before a hot work authorization can be issued?
The individuals conducting the operations must be able to perform them safely.
What is the requirement for the storage of LPG containers indoors?
Portable LPG containers over 16.4 oz must not be stored indoors in certain
occupancies.
What is the maximum capacity of oxidizing gas that can be stored without a
permit?
504 SCF of oxidizing gas (e.g., oxygen).
What is required for the issuance of a permit by the Fire Commissioner?
The location must be inspected and approved as acceptable for the practices.
What must be done if there is a change in occupancy or ownership?
A new permit must be issued.
What is the role of the Certificate of Fitness holder?
Responsible for ensuring compliance with fire safety regulations and procedures.
What is the maximum number of 100 lbs LPG containers that require a permit?
One 100 lbs LPG container requires a permit.
What is the requirement for temporary permits?
They may be valid from one day to 12 months depending on the need.
What must be done with hazardous materials at the end of the workday under a
citywide permit?
All hazardous materials must be removed from the location.