Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

MEDICAL GAS 6010 INSTALLERS LATEST ACTUAL EXAM WITH COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (100% VERIFIED ANSWERS) |ALREADY GRADED A+| ||PROFESSOR VERIFIED|| ||BRANDNEW!!!||

Beoordeling
-
Verkocht
-
Pagina's
42
Cijfer
A+
Geüpload op
19-03-2026
Geschreven in
2025/2026

MEDICAL GAS 6010 INSTALLERS LATEST ACTUAL EXAM WITH COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (100% VERIFIED ANSWERS) |ALREADY GRADED A+| ||PROFESSOR VERIFIED|| ||BRANDNEW!!!||

Instelling
MEDICAL GAS 6010 INSTALLERS
Vak
MEDICAL GAS 6010 INSTALLERS

Voorbeeld van de inhoud

1|Page


MEDICAL GAS 6010 INSTALLERS LATEST 2026-2027 ACTUAL EXAM
WITH COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS
(100% VERIFIED ANSWERS) |ALREADY GRADED A+| ||PROFESSOR
VERIFIED|| ||BRANDNEW!!!||

With the approval of the authority having jurisdiction, a zone valve
shall be permitted to be secured to prevent inappropriate access
in _ areas? A) anesthetizing B) critical care C) maternity D)
psychiatric or pediatric - ANSWER-D) psychiatric or pediatric



New or replacement valves are not required to _ ? A) be ball type
B) have copper tube extensions for brazing C) permit in line
serviceability D) use quarter turn to off - ANSWER-A) be ball type



A _ shutoff valve shall be placed at the immediate connection of
each source system to the distributing piping system? A) main B)
supply C) source D) zone - ANSWER-C) source



A _ shutoff valve shall be provided in the main supply line when
the source valve is not accessible from within the building served?
A) main B) supply C) service D) zone - ANSWER-A) main

,2|Page


_ valves shall be installed to allow modification of lateral branch
piping from a main or riser without shutting down the entire main,
riser, or facility? A) main B) riser C) service D) zone - ANSWER-
C) service



Regardless of how many zone valve boxes are installed on a
lateral branch off a riser, only one _ valve shall be required for
each branch? A) main B) riser C) service D) zone - ANSWER-C)
service



_ valves shall not be located in a room with station outlets or
inlets that it controls? A) main B) service C) source D) zone -
ANSWER-D) zone



_ valves shall be readily operable from a standing position in the
corridor on the same floor they serve? A) in-line B) relief C)
service D) zone - ANSWER-D) zone



Immediately outside of each vital life-support, critical care, and
anesthetizing location, there shall be a _ valve for each medical

,3|Page


gas, vacuum, and WAGD system? A) fire extinguisher B) local
alarm C) relief valve D) zone - ANSWER-D) zone



Operational _ shutoff valves shall be permitted to be installed to
isolate or shut off piping for servicing of individual rooms or
areas? A) in-line B) main line C) riser D) zone - ANSWER-A) in-
line



In-line check valves are not required to have _ ? A) brazed
extensions B) in-line serviceability C) threaded end connections
D) threaded purge ports - ANSWER-C) threaded end connections



Each station outlet/inlet for medical gasses and vacuums shall be
_ ? A) gas-specific B) interchangeable C) quick-coupler D)
threaded - ANSWER-A) gas specific



The factory installed tuning on station outlets and inlets shall
extend no further than _ in. from the body of the terminal? A) 6 B)
8 C) 10 D) 12 - ANSWER-B) 8

, 4|Page


Factory installed inlet tubing on station outlets shall not be less
than _ NPS? A) 1/4 B) 3/8 C) 1/2 D) 5/8 - ANSWER-A) 1/4



Factory installed outlet tubing on station inlets shall not be less
than _ NPS? A) 1/8 B) 3/16 C) 1/4 D) 3/8 - ANSWER-D 3/8



Station outlets that operate at a pressure in excess of _ PSI shall
be either D.I.S.S. or be designed to relieve pressure prior to
removal of adapter? A) 50 B) 60 C) 70 D) 80 - ANSWER-D) 80



The manufacturer is allowed a decay of less than _ % in 24 hours
during the standing pressure test? A) 3 B) 2 C) 1.5 D) 1.0 -
ANSWER-D) 1.0



The _ shall provide documentation certifying the performance and
successful completion of all pressure testing for a manufactured
assembly? A) engineer B) installer C) manufacturer D) owner -
ANSWER-C) manufacturer

Geschreven voor

Instelling
MEDICAL GAS 6010 INSTALLERS
Vak
MEDICAL GAS 6010 INSTALLERS

Documentinformatie

Geüpload op
19 maart 2026
Aantal pagina's
42
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$25.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TopGradeExams Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
129
Lid sinds
1 jaar
Aantal volgers
4
Documenten
4517
Laatst verkocht
3 dagen geleden
A+ PROFICIENT TUTOR

Need expert assistance with your studies and get A+? Worry no more. I offer top-tier tutoring and homework help in psychology, nursing, Human Resource Management, and Mathematics. As a tutor on Stuvia, I am committed to providing high-quality, scholarly work that meets academic standards. Whether it's for quizzes, exams, or assignments, I guarantee excellent grades. Rely on my expertise to achieve your academic goals!!!

4.1

21 beoordelingen

5
13
4
3
3
2
2
1
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen