Prepare with confidence for the ICC California Underground Storage Tank (UST) Inspector Certification Exam using this comprehensive and up-to-date study guide. This resource includes carefully compiled practice questions with 100% verified correct answers, designed to match the latest exam format and standards. Ideal for candidates seeking to pass on their first attempt, this guide covers key inspection principles, regulatory requirements, safety protocols, and real exam-style questions to boost your confidence and performance.

Meer zien Lees minder
Instelling
Icc California
Vak
Icc california

Voorbeeld van de inhoud

ICC California UST Inspector Exam With Complete Solutions 100%
Correct Latest Update

1.Single-wall UST Systems containing the following shall be upgraded to double-wall UST Systems
except for:

a.) Tanks containing liquids with a pH>13

b.) Waste oil tanks

c.) Solvent tanks

d.) Motor vehicle fuel tanks - ANSWER d.) Motor vehicle fuel tanks CCR

Title 23, Sec 2662(b)

2.What is interstitial monitoring used for:

a) To detect under-dispenser containment leaks.

b.) To detect the presence of liquid between the primary and secondary containment.

c.) To monitor tank volume.

d.) To control fuel flow to the dispenser. - ANSWER b.) To detect the presence of liquid
between the primary and secondary containment.



CCR Title 23, Sec 2611 'Interstitial

space' & 2632(b)

Underground storage tank that is installed after December 22, 1998 means

b. An underground storage tank that was installed after 1987

c. An underground storage tank that is not an existing underground storage

d. An underground storage tank that was installed after July 1, 2003 - ANSWER c. An
underground storage tank that is not an existing underground storage



CCR Title 23, Sec 2611

,The Federal law governing underground storage tank is know as:

a. The Underground Storage of Hazardous Substances Control Act

b. The Clean Water Act

c. The Safe Drinking Water Act

d. The Resource Conservation and Recovery Act, Subtitle I - ANSWER d. The Resource
Conservation and Recovery Act, Subtitle I



Which section of US Code is the Federal Act coded in?



a. The Underground Storage of Hazardous Substances Control Act

b. The Clean Water Act

c. The Safe Drinking Water Act

d. Subchapter IX of chapter 82 of Title 42 of the United States Code, as added by the
Hazardous and Solid Waste Amendments of 1984, or as it may subsequently be amended or
supplemented. - ANSWER d. Subchapter IX of chapter 82 of Title 42 of the United States Code,
as added by the Hazardous and Solid Waste Amendments of 1984, or as it may subsequently
be amended or supplemented.



H≻ 25281



California law requires that underground storage tanks be inspected every



a. Three years by the local agency.

b. Year by the designated operator

c. Year by the local agency

d. Two years by the local agency - ANSWER c. Year by the local agency



H≻ 25288

,Secondary containment was required for hazardous substance and petroleum underground
storage tanks installed after



a. December 22, 1998

b. July 1, 1991 for underground storage tanks and January 1, 1992 for piping

c. January 1, 1984

d. January 1, 2002 - ANSWER c. January 1, 1984



H≻ 25291 (a)



Secondary containment was required for all pressurized, petroleum underground piping installed
after



a. December 22, 1998

b. July 1, 2003

c. January 1, 1984

d. July 1, 1987 - ANSWER d. July 1, 1987



H≻ 25291 (a)(7)(E)



All of the following shall be marked on the exterior surface of an underground storage tank,
EXCEPT?



a. Maximum operating temperature in degrees Fahrenheit

b. Nominal Capacity in gallons

c. Useable capacity in gallons

d. City and State of manufacture - ANSWER d. City and State of manufacture

, CCR; 2631 (b)



What is the minimum thickness of a steel of a striker plate?

a. 1/8 inch

b. 2 inches lager than the opening it lies beneath

c. ¼ inch

d. ½ inch - ANSWER a. 1/8 inch



CCR; 2631 (c)



All of the following is required to be included in an UST written monitoring procedure, EXCEPT:



a. The methods and equipment, identified by name and model

b. The names and titles of the persons responsible for monitoring the equipment.

c. The name of the emergency coordinator

d. A description of the training required for the operation of the tank system. - ANSWER
c. The name of the emergency coordinator



CCR; 2632



All of the following are exempt from regulation as an UST, EXCEPT:



a. A 1000 gallon UST on a farm

b. Drums in basements that contain 55 gallons or less

c. Liquid asphalt tank

d. A bulk field constructed UST - ANSWER d. A bulk field constructed UST

Geschreven voor

Instelling
Icc california
Vak
Icc california

Documentinformatie

Geüpload op
20 maart 2026
Aantal pagina's
139
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$14.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
wisenurse Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
23
Lid sinds
7 maanden
Aantal volgers
2
Documenten
639
Laatst verkocht
1 week geleden
wisenurse study hub

Top-Rated Study Guides, Test Banks & Solution Manuals for Nursing, Accounting, Chemistry, Statistics, Biology & Other Subjects Welcome to Your wisenurse Study Resource Hub! Looking for high-quality, reliable, and exam-ready study materials? You’re in the right place. Our shop specializes in original publisher content, including solutions manuals, test banks, and comprehensive study guides that are ideal for university and college students across various subjects. Every document is in PDF format and available for instant download—no waiting, no hassle. That means you get immediate access to top-tier academic resources the moment you need them, whether you\'re cramming for an exam or studying ahead. These materials are especially effective for exam preparation, offering step-by-step solutions, real test formats, and well-organized study guides that align with your coursework and textbooks. Whether you\'re a visual learner, a problem-solver, or need practice questions—there’s something for every study style.

Lees meer Lees minder
5.0

1 beoordelingen

5
1
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen