Leaving work area procedure - ANSWERS--HEPA vacuum
yourself
-wash tools with amended water
-throw coverall away
-shower with respirator on
-clean respirator
-dry with paper towels in clean room
-retrieve license
-sign logbook
when do you need a separate waste decon unit? -
ANSWERS-for all large asbestos projects
(projects >= 1000sq.ft or 100 linear ft)
, when is the decontamination unit set up? - ANSWERS-
before preparing the work area
what do you need additionally for remote or distant
decontamination units? - ANSWERS--2 disposable suits,
remove one and put another on when exiting work area.
-extra airlock for work area and equipment room or decon
unit
what must stay up until final clearance? - ANSWERS--critical
barriers
-decon unit
-negative air filtration unit (microtrap)
work area must have: - ANSWERS--warning signs
-"lock out and tag out"
-GFCI
-Seal all HVAC openings with 2 layers independently
-when the opening is more than 32sqft we need to put up a
solid barrier