and answers | Updated RATED A+| 2026
What digital fluoroscopic imaging technique u lizes changing masks, which provides
informa on of changes in contrast media content within a structure
1.Time interval difference imaging
2. Mask mode fluoroscopy
3. K -edge fluoroscopy
4. Synchronized fluoroscopy
1. Time interval difference imaging
All of the following will directly influence the table-top exposure rate except
1. Light in the fluoroscopy room
2. kVp
3. Target to panel distance
4. Filtra on
1. Light in the fluoroscopy room
A.enua on of a radia on beam's intensity as it passes through an absorber is governed by
1. Time
2. The specific mediums density
3. The energy of the radia on
4. The thickness of the absorber traversed
2. The specific mediums density
3. The energy or radia on
4. The thickness of the absorber traversed
What recording medium will result in the least recorded resolu on
1. Spot films using a spot film camera
2. video tape recording
3. spot films using conven onal casse.es
4. video disc recording
2. video tape recording
During the period when an individual receives an occupa onal dose, they are _ considered to
be a "member of the public"
,1. some mes
2. always
3. it depends
4. never
4.never
A person wearing a _ apron will reduce transmi.ed exposure to approximately 99.9% of the
incident sca.er dose
1. 1.5 mm Pb equivalent
2. 0.50 mm Pb equivalent
3. 0.25 mm Pb equivalent
4. 1.0 mm Pb equivalent
2. 0.50 mm Pb equivalent
If the input phosphor of an image intensifier measures 15 inches in diameter and the output
phosphor measures 1.0 inches, the minifica on gain would be
1. 30
2. 225
3. 175
4. 300
Minifica on Gain = {15(2) = 225} input screen diameter (2) / {1.0 (2) = 1} output screen
diameter (2) = 225/1= 225
What electronic system is designed to help maintain a consistent level of image brightness
1. photo-emi.er
2. automa c brightness stabilizer
3. camera control unit
4. vidicon
2. automa c brightness stabilizer
Energy subtrac on as used in digital fluoroscopy exhibits less _ than temporal subtrac on
1. complexity
2. x-ray intensity
3. kVp
4. mo on ar fact
4. mo on ar fact
,Bone marrow dose is measured
1. directly from bone marrow
2. as es mate from gonadal dose
3. as an es mate from ESE
4. directly from the beam
3. as an es mate from the ESE
The Privacy Rule is meant to ensure that there is/are
1. security of electronic personal health informa on
2. standardiza on of electronic pa ent health data
3. limits PHI to a "need to know.." basis to carry out medical treatment
4. all the listed answers
4. all the listed answers
To provide illumina on stability of the virtual image during fluoroscopy, most modern units will
automa cally adjust radia on levels for more dense and more radiolucent body parts. This
func onality is known as:
1. velling glare
2. image flare
3. automa c adap on
4. automa c brightness control
4. automa c brightness control
The electronic signal which carries image informa on from a television camera to a viewing
monitor is termed the:
1. video signal
2. return beam
3. synchroniza on pulse
4. bandpass
1. video signal
If only one personnel monitoring device is worn, it must be located
1. under the apron at the collar level
2. outside the apron at the gonad level
3. outside the apron at the collar level
3. outside the apron at the collar level
, The random pa.ern of incident radia on, which oHen results in the appearance of "snow" or
"mo.le" when viewing the virtual image is called
1. flicker effect
2. lens opacity
3. quantum noise
d. vigneIng
3. quantum noise
When wearing a "film badge" as a personnel monitoring device, it must be posi oned
1. at waist level
2. at collar level
3. under the protec ve apron
4. outside the protec ve apron
b. 2 and 4
Which of the following are considered to be advantages of using a film badge for radia on
monitoring
1. inexpensive
2. reusable
3. provides a permanent record
4. provides an objec ve review of exposure history
c. 1 and 3
which of the following statements is true with respect to obtaining a medical history for a
radiographic examina on
1. should include any per nent informa on about the pa ent and indicated the reason for the
examina on
2. is not considered confiden al informa on
3. required only for inpa ents
4. is always obtained by the radiologist
1. should include any per nent informa on about the pa ent and indicated the reason for the
examina on
In a television system, the ra o between the ver cal resolu on and the number of horizontal
scan lines is called the
1. line rate factor
2. kell factor