CALIFORNIA LEAD ABATEMENT SUPERVISOR
||VERIFIED EXAM!!|| MOST RECENT EXAM ACTUAL
COMPLETE REAL EXAM QUESTIONS AND CORRECT
ANSWERS (VERIFIED ANSWERS) ALREADY GRADED
A+!! NEWEST EXAM!!
The chemical symbol for lead is: - Answer-Correct Answer:
Pb
Subsection (e) of the Cal/OSHA Construction Standard for
lead requires the employer to reduce or maintain
employee exposure at or below the PEL utilizing: -
Answer-Correct Answer. A written compliance program,
mechanical ventilation, administrative controls, and
engineering and work practiced controls
Effective August 14, 2009 CPSC reduced the allowable
lead content for paint and similar 0.06% surface-coating
materials for consumer use that contain lead or lead
compounds from (600 ppm) to parts per million, based on
a dried paint film. - Answer-Correct Answer: 90
,2|Page
Methylene chloride is a common chemical used in paint
strippers. According to the text: - Answer-Correct Answer:
Methylene chloride is not recommended on HUD projects
Which of the following symptoms in a worker would
indicate a possible elevated blood lead level (BLL): -
Answer-Correct Answer: Joint or muscle aches
Which of the following statements is true concerning
"chelation"?
A. Chelation can be used to keep employee blood lead
levels low so they can remain working on lead jobs.
B. Chelation can only be administered by a licensed
physician.
C. Chelation can only be administered by your employer
with the permission of a licensed physician.
D. Chelation is a type of electrode-shock therapy. -
Answer-Correct Answer: Chelation can only be
administered by a licensed physician.
When performing an interior abatement on walls where
lead-based paint is already in damaged condition it would
be important to: - Answer-Correct Answer:
, 3|Page
Perform some pre-cleaning of interior lead dust and debris
before placing plastic drop sheeting on floors
Which of the following CDPH Certified individuals can
perform clearance of an abatement area? - Answer-
Correct Answer: A Project Monitor
The OSHA Lead Construction Standard, 8 CCR 1532.1,
applies to: - Answer-Correct Answer: Construction
activities that disturb paint with any detectable level of
lead.
What are the minimum and maximum employee air
monitoring flow rates according to NIOSH Method 7082? -
Answer-Correct Answer: 1.0 to 4.0 LPM
Cal/OSHA's Respiratory Protection Standard (8 CCR
5144) requires fit testing for: - Answer-Correct Answer: all
tight-fitting respirators
EPA is the federal government agency that controls the
disposal of solid waste. Which of the following California
State agencies also controls the disposal of solid waste? -
Answer-Correct Answer: DTSC