Voorbeeld van de inhoud

Medical Gas 6010 Installers Exam Newest
Exam 2026 | All Questions and Correct
Answers | Verified Answers | Just Released

A medical-surgical vacuum receiver shall be made serviceable by _ ? A) a three-
valve bypass B) any method to ensure the continuation of service C) being valved
at the end of the main line D) shutting down the system ---------CORRECT
ANSWER-----------------B) any method to ensure the continuation of service




When a medical-surgical vacuum source in operation is incapable of adequately
maintaining the required vacuum, additional pump shall be _ activated? A)
automatically B) manually C) remotely D) systematically ---------CORRECT
ANSWER-----------------A) automatically




The vacuum exhaust shall discharge a minimum of _ ft. from any door, window,
air intake, or place of public assembly? A) 10 B) 15 C) 20 D) 25 ---------CORRECT
ANSWER-----------------D) 25




A medical-surgical vacuum exhaust shall be turned down and screened. The
screening shall be fabricated using _ material? A) any non-corroding B) chicken
wire C) steel mesh D) steel wire ---------CORRECT ANSWER-----------------A) any non-
corroding

,Multiple vacuum pumps shall be permitted to be joined together to one common
exhaust provided the common exhaust is sized to _ ? A) minimize back pressure
B) peak calculated demand C) prevent backflow D) the largest pump ---------
CORRECT ANSWER-----------------A) minimize back pressure




Vacuum exhaust from multiple pumps joined together to one common exhaust
shall be permitted provided each pump can be isolated. The pumps can be
isolated by all of the following except a _ ? A) blind flange B) check valve C)
grooved joint D) manual valve ---------CORRECT ANSWER-----------------C) grooved
joint




Category 1 medical-surgical vacuum systems shall activate a _ alarm when the
backup or lag pump is running? A) local B) main C) source D) warning ---------
CORRECT ANSWER-----------------A) local




WAGD shall be permitted to be produced by all of the following except a _ ? A)
dedicated producer B) medical surgical-vacuum source C) medical air source D)
venturi ---------CORRECT ANSWER-----------------C) medical air source




A category 1 dedicated WAGD source shall consist of _ or more producers, and
each shall be sufficient to serve the peak calculated demand? A) 1 B) 2 C) 3 D) 4 ---
------CORRECT ANSWER-----------------B) 2

,_ shall not be used to power the venture of a WAGD system? A) inert gas B)
instrument air C) medical air D) water ---------CORRECT ANSWER-----------------C)
medical air




WAGD producers designed for operation at vacuums below _ in. HgV shall only be
used for WAGD service? A) 2 B) 3 C) 4 D) 5 ---------CORRECT ANSWER-----------------
D) 5




A WAGD source system shall activate a _ alarm when the backup or lag producer
is running? A) local B) main C) source D) warning ---------CORRECT ANSWER----------
-------A) local




Additional WAGD producers shall _ activate when the producer in operation is
incapable of maintaining the required vacuum? A) automatically B) manually C)
remotely D) systematically ---------CORRECT ANSWER-----------------A) automatically




With the approval of the authority having jurisdiction, a zone valve shall be
permitted to be secured to prevent inappropriate access in _ areas? A)
anesthetizing B) critical care C) maternity D) psychiatric or pediatric ---------
CORRECT ANSWER-----------------D) psychiatric or pediatric

, New or replacement valves are not required to _ ? A) be ball type B) have copper
tube extensions for brazing C) permit in line serviceability D) use quarter turn to
off ---------CORRECT ANSWER-----------------A) be ball type




A _ shutoff valve shall be placed at the immediate connection of each source
system to the distributing piping system? A) main B) supply C) source D) zone ------
---CORRECT ANSWER-----------------C) source




A _ shutoff valve shall be provided in the main supply line when the source valve
is not accessible from within the building served? A) main B) supply C) service D)
zone ---------CORRECT ANSWER-----------------A) main




_ valves shall be installed to allow modification of lateral branch piping from a
main or riser without shutting down the entire main, riser, or facility? A) main B)
riser C) service D) zone ---------CORRECT ANSWER-----------------C) service




Regardless of how many zone valve boxes are installed on a lateral branch off a
riser, only one _ valve shall be required for each branch? A) main B) riser C)
service D) zone ---------CORRECT ANSWER-----------------C) service




_ valves shall not be located in a room with station outlets or inlets that it
controls? A) main B) service C) source D) zone ---------CORRECT ANSWER-------------
----D) zone

Geschreven voor

Instelling
Medical Gas 6010 Installers
Vak
Medical Gas 6010 Installers

Documentinformatie

Geüpload op
24 maart 2026
Aantal pagina's
77
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$25.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
StudyWay Capella University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
126
Lid sinds
2 jaar
Aantal volgers
43
Documenten
2146
Laatst verkocht
1 week geleden
INVEST AND UNLEASH THE POWER OF KNOWLEDGE NOW!

THIS PREMIUM STUVIA ACCOUNT GIVES YOU ACCESS TO EXCLUSIVE EXAMS, FLASH CARDS, TEST BANKS, AND STUDY GUIDES TAILORED FOR YOUR SUCCESS. ELEVATE YOUR GRADES, ACCELERATE YOUR LEARNING, AND SUPERCHARGE YOUR STUDIES: DIVE INTO A WORLD OF ACADEMIC EXCELLENCE!

4.4

64 beoordelingen

5
48
4
5
3
3
2
2
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen