NFPA 99 MedGas for 6010 Installer Exam 2026
| All Questions and Correct Answers | Verified
Answers | Just Released

All cryogenic fluid systems shall be provided with an auxiliary source connection
point the same size as the main line. Which is true?
A. it shall be located immediately on either side of the source valve
B. it shall consist of a tee, a valve, and a plug or cap brazed in place
C. it shall normally be kept closed and secured
D. both B & C ---------CORRECT ANSWER-----------------it shall normally be kept
closed and secured




Which of the following is NOT permitted for the check valves in an ESOC?
A. brass or bronze material
B. brazed extensions
C. threaded connections
D. threaded purge points 1/8" NPT ---------CORRECT ANSWER-----------------
threaded vonnections




In these portions of systems intended to handle oxygen at pressures greater than
350psi, the interconnection hoses shall NOT contain _____? ---------CORRECT
ANSWER-----------------polymeric

,The ESOC shall be installed on the exterior of the building being served, protected
from physical damage, and with a minimum of how many feet of clearance
around the connection? ---------CORRECT ANSWER-----------------3




Medical air intakes shall maintain a minimum distance of how many feet from the
areas where noxious fumes can collect? ---------CORRECT ANSWER-----------------25




Two or more medical gas piping systems shall NOT be interconnected EXCEPT
_____ ---------CORRECT ANSWER-----------------medical gas systems with the same
contents




NFPA 99 requires that flexible connectors connected with manufactured
assemblies shall include all EXCEPT which of the following?
A. date of installation
B. name of gas or vacuum system
C. negative operating pressure
D. system color code ---------CORRECT ANSWER-----------------negative operating
pressure




Oxygen central supply systems with an oxygen concentrator, having three supply
sources, shall NOT be allowed if _____ ---------CORRECT ANSWER-----------------a
documented risk analysis has NOT been completed

,Which of the following risk categories does NOT permit medical gases?
A. Category 1 piped gas and vacuum systems
B. Category 2 sources
C. Category 3 dental gas & vacuum systems
D. each of these categories may permit medical gases ---------CORRECT ANSWER---
--------------each of these categories may permit medical gases




In accordance with NFPA 99, central supply systems for nonflammable medical
gas systems shall be inspected with what frequency? ---------CORRECT ANSWER----
-------------annually




Which portion of the central supply system is supplying the piping system at the
time of observation? ---------CORRECT ANSWER-----------------operating supply




In a dental gas system the initial cross connection test of copper medical gas
distribution piping requires the piping to be pressurized to how many psi? ---------
CORRECT ANSWER-----------------50




Those portions of the central supply system that act as a self-contained supply are
known as _____ ---------CORRECT ANSWER-----------------supply source

, Support gases used for powering tools include all EXCEPT which of the following?
A. dental air
B. helium
C. instrument air
D. nitrogen ---------CORRECT ANSWER-----------------helium




Which of the following is a requirement for the configuration of a zone valve box?
A.located in the room it serves
B. locked so that the valves are inaccessible to the public
C. placed so that a wall intervenes between the valve and the inlets/outlets that it
controls
D. serve inlets/outlets located on 2 or more floors ---------CORRECT ANSWER--------
---------placed so that a wall intervenes between the valve and the inlets/outlets
that it controls




According to NFPA 99, which of these procedures must be followed and
documented to determine which relevant category for medical gases the facility
would fall under?
A. Defined Risk Assessment procedure
B. Facility Survey
C. Gas Analysis

Geschreven voor

Instelling
NFPA 99 MedGas for 6010 Installer
Vak
NFPA 99 MedGas for 6010 Installer

Documentinformatie

Geüpload op
24 maart 2026
Aantal pagina's
60
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$29.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
StudyWay Capella University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
126
Lid sinds
2 jaar
Aantal volgers
43
Documenten
2146
Laatst verkocht
1 week geleden
INVEST AND UNLEASH THE POWER OF KNOWLEDGE NOW!

THIS PREMIUM STUVIA ACCOUNT GIVES YOU ACCESS TO EXCLUSIVE EXAMS, FLASH CARDS, TEST BANKS, AND STUDY GUIDES TAILORED FOR YOUR SUCCESS. ELEVATE YOUR GRADES, ACCELERATE YOUR LEARNING, AND SUPERCHARGE YOUR STUDIES: DIVE INTO A WORLD OF ACADEMIC EXCELLENCE!

4.4

64 beoordelingen

5
48
4
5
3
3
2
2
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen