Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

EPA 608 Type I Test Exam 2026–2027 – Complete 210 Questions with Verified Answers

Beoordeling
-
Verkocht
-
Pagina's
32
Cijfer
A+
Geüpload op
25-03-2026
Geschreven in
2025/2026

This document contains the EPA 608 Type I certification exam, including 210 questions with fully verified correct answers. It covers key topics such as refrigerant handling, leak detection, recovery and recycling procedures, and environmental safety standards required for certification. The material reflects the latest 2024–2025 updates and 2026–2027 exam standards, providing a comprehensive resource for study and guaranteed exam readiness.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

1|Pag e


EPA 608 TYPE 1 TEST EXAM|| 2026-2027 LATELY
UPDATED 210 QUESTIONS AND 100% CORRECT
ANSWERS ALREADY GRADED A+|| LATEST AND
COMPLETE UPDATE 2024-2025 WITH VERIFIED
SOLUTIONS|| ASSURED PASS!!!
Recovery equipemnt used for the service or repair of small appliances must be
certified by an EPA approved lab if the recovery equipment was made after -
ANSWER: November 15, 1993




Recovery devices made before 11-15-93 and are used for recovery of refrigerant
from small appliances must be capable of: - ANSWER: recovering 80% of the
refrigerant whether or not the compressor is operating or achieving a 4 inch
vacuum under conditions of ARI 740-1993




EPA's definition of a small appliance includes: - ANSWER: a device
manufactored, charges & hermeticly sealed in factory with a charge of 5lbs or less




Tech's with a type 1 small appliance certification are certified to recover refrigerant
during the maintenance or repair of: - ANSWER: PTAC's with 5lbs or less of
refrigerant




EPA requires that all small appliances be equipped with a service aperture or other
device that is used when adding or removing refrigerant from the appliance. For
small appliances this service port typically - ANSWER: a straight piece of tubing,
called a process tube that is entered using a piercing valve

,2|Pag e




The EPA section 608 certification must be renewed every - ANSWER: never




It is an EPS regulation that any person who opens and appliance for maintenance,
service or repair must have at least one self-contained recovery machine avalible at
their place of buisiness. The only exception to this rule are persons working on -
ANSWER: small appliances




The sale od CFC & HCFC refrigerants is: - ANSWER: restricted to techs who are
EPA certified in refrigerant recovery




Anyone who recovers refrigeration during maintenance, service or repair of small
appliances must be certified as either a universal Tech or a: - ANSWER: Type 1
tech




When recovering refrigerant from a household refrigerator who's compressor does
not run, it is recommended that a low and high side access valves be installed
because: - ANSWER: it can help speed of recovery and required recovery effiency




If you install an access fitting into a sealed system: - ANSWER: the fitting should
be leak tested before proceeding with recovery

,3|Pag e




Before beginning a refrigerant recovery procedure it is alway necessary to: -
ANSWER: determine the type of refrigerant in the system




when recovering refrigerant into a non-pressurized container from a refrigerator
with an improper compressor: - ANSWER: it is necessary to heat & strike the
compressor with a rubber mallet




When checking for the existence of noncondensable gases inside a recovery
cyclinder, why is it proper procedure to allow the temperature of the cyclinder to
stabilize @ room temperature before taking a pressure reading? - ANSWER: any
comparisons to a pressure-temperature chart is only valid if both the pressure &
temperature of the refrigerant are stable




A recovery cyclinder which is 1/2 full of recovered R-410A @ 90*F, in the
absence of non-condensables will be presurized to: - ANSWER: 300 psig.




When using , it is essential to take extra measures (heating/striking), to help
release trapped refrigerant from the compressor oil. - ANSWER: passive system-
dependdent recovery devices on a small appliance with a non-operating
compressor.




According to the EPA which recovery equipment maintenance practice(s) should
be preformed on a regular basis? - ANSWER: check recovery device for
refrigerant leaks

, 4|Pag e




On a small appliance with an operating compressor that has a completely plugged
capillary tube, what is the minimum number of access valves that are needed to
evacuate the refrigerant - ANSWER: 1 valve on the high side


Which refrigerant is most commonly used as a replacement for R-12 in new
household refrigerators - ANSWER: R-134a




Small amounts of refrigerant have no odor, therefor a pungent odor is detected
during a system recovery &/or repair: - ANSWER: a compressor burn-out has
likely occurred




If R-22 or R-12are exposed to high temperatures, these refrigerants can decompose
to form: - ANSWER: hydrochloric & hydroflouric acids




Large spills of refrigerant can cause suffocation because: - ANSWER: they are
heavier than air & displace oxygen




In the event of a large release of R-12 or R-22 in a contained area - ANSWER:
you should wear a "SCBA" or leave the area is required

Geschreven voor

Vak

Documentinformatie

Geüpload op
25 maart 2026
Aantal pagina's
32
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TopGradeSolutions Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
95
Lid sinds
2 jaar
Aantal volgers
9
Documenten
13297
Laatst verkocht
2 uur geleden
TOPGRADESOLUTIONS

Here we offer revised study materials to elevate your educational outcomes. We have verified learning materials (Research, Exams Questions and answers, Assignments, notes etc) for different courses guaranteed to boost your academic results. We are dedicated to offering you the best services and you are encouraged to inquire further assistance from our end if need be. Having a wide knowledge in Nursing, trust us to take care of your Academic materials and your remaining duty will just be to Excel. Remember to give us a review, it is key for us to understand our clients satisfaction. We highly appreciate clients who always come back for more of the study content we offer, you are extremely valued. All the best.

Lees meer Lees minder
4.9

171 beoordelingen

5
159
4
7
3
4
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen