AIS 2A0X1M SKT-A Prep Questions With
Correct Answers
What device provides the 115 VAC, 400 Hz facility power input to a test station? -
| | | | | | | | | | | | | | | |
CORRECT ANSWER✔✔-Input power generator
| | |
What should you do if you accidentally drop a torque wrench? - CORRECT
| | | | | | | | | | | | |
ANSWER✔✔-Have it recalibrated | |
What are the two basic types of maintenance? - CORRECT ANSWER✔✔-On-
| | | | | | | | | |
equipment and off-equipment | |
When you receive a WFOV HUD the electrical connectors should be inspected for
| | | | | | | | | | | |
- CORRECT ANSWER✔✔-Bent, broken or missing pins
| | | | | | |
Which ESTS ITA is required to test the WFOV HUD? - CORRECT ANSWER✔✔-ITA 4
| | | | | | | | | | | | |
On ESTS, how many people are required to lift ITA 4? - CORRECT ANSWER✔✔-
| | | | | | | | | | | | |
Two
What are the three maintenance levels? - CORRECT ANSWER✔✔-Depot,
| | | | | | | | |
intermediate and organizational. | |
, What projects an image on the WFOV HUD combining glass? - CORRECT
| | | | | | | | | | | |
ANSWER✔✔-A CRT |
If the WFOV HUD has failed BIT test, the BIT indicator will show what color? -
| | | | | | | | | | | | | | | |
CORRECT ANSWER✔✔-White |
What is the correct 400 Hz voltage indication on the PDP in the EARTS station? -
| | | | | | | | | | | | | | | |
CORRECT ANSWER✔✔-Between 108, 118 VAC
| | | |
On EARTS Channel A, what will happen if you press the fault indicator on the
| | | | | | | | | | | | | | |
1A2A4? - CORRECT ANSWER✔✔-Terminate testing
| | | |
Which radio frequency (RF) component is used to sample an input signal and
| | | | | | | | | | | | |
does not have any moving parts? - CORRECT ANSWER✔✔-Directional coupler
| | | | | | | | |
What is a power sensor really considered to be? - CORRECT ANSWER✔✔-
| | | | | | | | | | |
Transducer
What must be done to the meter and power sensor before using them? -
| | | | | | | | | | | | | |
CORRECT ANSWER✔✔-Calibrate them together
| | |
Why should system power be turned off when removing the top cover of the
| | | | | | | | | | | | | |
WFOV HUD - CORRECT ANSWER✔✔-High voltages in the Power Supply PS2
| | | | | | | | | |
Where is the ESTS emergency power off switch located? - CORRECT ANSWER✔✔-
| | | | | | | | | | |
Power Control Unit (PCU)
| | |
Correct Answers
What device provides the 115 VAC, 400 Hz facility power input to a test station? -
| | | | | | | | | | | | | | | |
CORRECT ANSWER✔✔-Input power generator
| | |
What should you do if you accidentally drop a torque wrench? - CORRECT
| | | | | | | | | | | | |
ANSWER✔✔-Have it recalibrated | |
What are the two basic types of maintenance? - CORRECT ANSWER✔✔-On-
| | | | | | | | | |
equipment and off-equipment | |
When you receive a WFOV HUD the electrical connectors should be inspected for
| | | | | | | | | | | |
- CORRECT ANSWER✔✔-Bent, broken or missing pins
| | | | | | |
Which ESTS ITA is required to test the WFOV HUD? - CORRECT ANSWER✔✔-ITA 4
| | | | | | | | | | | | |
On ESTS, how many people are required to lift ITA 4? - CORRECT ANSWER✔✔-
| | | | | | | | | | | | |
Two
What are the three maintenance levels? - CORRECT ANSWER✔✔-Depot,
| | | | | | | | |
intermediate and organizational. | |
, What projects an image on the WFOV HUD combining glass? - CORRECT
| | | | | | | | | | | |
ANSWER✔✔-A CRT |
If the WFOV HUD has failed BIT test, the BIT indicator will show what color? -
| | | | | | | | | | | | | | | |
CORRECT ANSWER✔✔-White |
What is the correct 400 Hz voltage indication on the PDP in the EARTS station? -
| | | | | | | | | | | | | | | |
CORRECT ANSWER✔✔-Between 108, 118 VAC
| | | |
On EARTS Channel A, what will happen if you press the fault indicator on the
| | | | | | | | | | | | | | |
1A2A4? - CORRECT ANSWER✔✔-Terminate testing
| | | |
Which radio frequency (RF) component is used to sample an input signal and
| | | | | | | | | | | | |
does not have any moving parts? - CORRECT ANSWER✔✔-Directional coupler
| | | | | | | | |
What is a power sensor really considered to be? - CORRECT ANSWER✔✔-
| | | | | | | | | | |
Transducer
What must be done to the meter and power sensor before using them? -
| | | | | | | | | | | | | |
CORRECT ANSWER✔✔-Calibrate them together
| | |
Why should system power be turned off when removing the top cover of the
| | | | | | | | | | | | | |
WFOV HUD - CORRECT ANSWER✔✔-High voltages in the Power Supply PS2
| | | | | | | | | |
Where is the ESTS emergency power off switch located? - CORRECT ANSWER✔✔-
| | | | | | | | | | |
Power Control Unit (PCU)
| | |