S-98 Test
1. Who is responsible for alarm system testing and maintenance?: The property owner
INSPECTION TESTING AND MAINTANCE
14.2.3.2
2. At minimum, how long shall a supervising station maintain records on signals
received from maintenance, inspections and testing?: 36 months
3. According to NFPA 72, how often shall manual fire alarm pull stations be tested?:
Every 12 months
4. According to NFPA 72, How often should water flow switches be tested?: Quarterly
5. What standard covers the installation of audible and visible notifications
appliances?: NFPA 72 2007, Ch. 7
6. How many smoke detectors are required for a room with a level ceiling of a
900 square feet or less?: 1 (72-101)
7. Fire alarm system providing general emergency voice alarm communication must
provide for _________ hours of stand by power followed by ___________ minutes of
alarm.: 24; 15
8. A fire alarm system in which components are used in whole or in part, in common with
a non-fire signaling system.: A combination system
9. A system component that generates transmission of a change of state condition is
called an ___________.: Initiating device
10. Indicates the need for action in relation to the equipment or maintenance features
to related systems: Supervisory Signal
11. An individual that is designated by the building owner can be an ___________.-
: Impairment coordinator
12. Trouble signals and their restoration to normal shall be indicated within
_________.: 200 seconds
13. A fire alarm control panel shall recharge batteries within _________ after fully
charged batteries have been subject to a single discharge.: 48 hours
14. Fire alarm systems providing general evacuation need to provide ________ of
standby power, followed by a _________ of alarm power.: 24 hours; 15 minutes
15. If an engine driven generator dedicated to the fire alarm is used as a power source
shall comply with __________: NFPA 110


, 16 A Self-restoring supervisory signal shall be visually and audibly indicated within: 90
seconds
17. A coded alarm consists of not less that complete three rounds of the number
transmitted, each round shall consist of not less than ___________: Three Impulses
18. A coded supervisory signal shall be permitted to consist of _________ if the number
transmitted to indicate a supervisory off-normal condition: Two rounds
19. Required signals shall not be lost, interrupted or delayed by more than
________ as a result of the primary power failure.: 10 seconds
20. If an engine driven generator dedicated to the fire alarm system is used as a power
source, the operation of the generator shall comply with ___________.: NFPA
110
21. Rechargeable batteries shall be either __________ or __________: Trickle; Float-
Charged
(pick only one if both not listed)
22. Required signals shall not be interrupted or delayed by more than _______ as a
result of a primary power failure: 10 seconds
23. A self-restoring supervisory signal shall be visually and audibly indicated within
_______: 90 Seconds
24. An engine driven generator for public fire alarm reporting system __________.-
: Shall be tested weekly
25. The temperature classification a heat-sensing fire detector with a green color code
means __________.: very extra high
26. The standard fire alarm evacuation signal is a _________ temporal pattern: three
pulse
27. 20. Smoke detectors mounted on a flat ceiling shall be no closer than _______ from
the surface wall: 4 inches
28. Smoke detectors are required to be installed within _________ of a peeked ceiling
.: 3 Feet
29. _______ is the color classification for heat detector rated at _______.: Blue; 275F
30. _______ smoke detector is required for a room with a level ceiling of 900 sq. ft. or
less.: One

Written for

Institution
S-98 FDNY Cert
Course
S-98 FDNY Cert

Document information

Uploaded on
March 25, 2026
Number of pages
10
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.69
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
stuviaexams stuvia
Follow You need to be logged in order to follow users or courses
Sold
45
Member since
1 year
Number of followers
3
Documents
1155
Last sold
2 days ago
EXAM Study Vault

EXAM Study Vault! I provide high-quality, clear, and well-organized study materials to help students pass their exams with confidence. My notes, summaries, and exam guides are designed to be easy to understand, time-saving, and focused on what really matters for success. Whether you are preparing for exams or other courses, you will find reliable resources here to support your learning and boost your grades. Thank you for supporting my store, and I wish you success in your studies!

Read more Read less
3.8

5 reviews

5
3
4
0
3
1
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions