3/26/26, 6:09 PM EPA 608 Type 2 Practice EXAM, Complete Test || Questions and Answers (Verified Answers) (Latest Update 2026) UPDATE!! Flash…
EPA 608 Type 2 Practice EXAM, Complete Test ||
Questions and Answers (Verified Answers) (Latest
Update 2026) UPDATE!!
Save
Terms in this set (25)
If a leaking appliance with a B
regulated refrigerant is not going to retrofitted or retired within 12 months.
be repaired, it must be;
A retrofitted or retired within 3
months.
B retrofitted or retired within 12
months.
C replaced within 3 months.
D replaced within 12 months.
A high-pressure appliance B 10 inches of vacuum
containing 210 lbs. of R-407C
refrigerant must be evacuated
(recovered) to a level of;
A 15 inches of vacuum
B 10 inches of vacuum
C 4 inches of vacuum
D 0 inches of vacuum
https://quizlet.com/1160809231/epa-608-type-2-practice-exam-complete-test-questions-and-answers-verified-answers-latest-update-2026-update-flas… 1/10
, 3/26/26, 6:09 PM EPA 608 Type 2 Practice EXAM, Complete Test || Questions and Answers (Verified Answers) (Latest Update 2026) UPDATE!! Flash…
What conditions allow for a system A
to be opened and repaired without A system with a large leak and internal pressure of
recovering the refrigerant to the 0 psig
required vacuum level?
A A system with a large leak and
internal pressure of 0 psig
B A system that is undergoing a
major component replacement
C A system that uses a CFC
refrigerant
D A system that has a non-
operational compressor
A crankcase heater is often used to A
prevent refrigerant from mixing with Low ambient temperature
compressor oil during periods of:
ALow ambient temperature
B High ambient temperature
C Low humidity
D High humidity
Leaks must be repaired on industrial C
process and refrigeration units with a 30%
50-pound charge or greater when
the annualized leak rate reaches _____
or more.
A 10%
B 20%
C 30%
D 40%
https://quizlet.com/1160809231/epa-608-type-2-practice-exam-complete-test-questions-and-answers-verified-answers-latest-update-2026-update-flas… 2/10
EPA 608 Type 2 Practice EXAM, Complete Test ||
Questions and Answers (Verified Answers) (Latest
Update 2026) UPDATE!!
Save
Terms in this set (25)
If a leaking appliance with a B
regulated refrigerant is not going to retrofitted or retired within 12 months.
be repaired, it must be;
A retrofitted or retired within 3
months.
B retrofitted or retired within 12
months.
C replaced within 3 months.
D replaced within 12 months.
A high-pressure appliance B 10 inches of vacuum
containing 210 lbs. of R-407C
refrigerant must be evacuated
(recovered) to a level of;
A 15 inches of vacuum
B 10 inches of vacuum
C 4 inches of vacuum
D 0 inches of vacuum
https://quizlet.com/1160809231/epa-608-type-2-practice-exam-complete-test-questions-and-answers-verified-answers-latest-update-2026-update-flas… 1/10
, 3/26/26, 6:09 PM EPA 608 Type 2 Practice EXAM, Complete Test || Questions and Answers (Verified Answers) (Latest Update 2026) UPDATE!! Flash…
What conditions allow for a system A
to be opened and repaired without A system with a large leak and internal pressure of
recovering the refrigerant to the 0 psig
required vacuum level?
A A system with a large leak and
internal pressure of 0 psig
B A system that is undergoing a
major component replacement
C A system that uses a CFC
refrigerant
D A system that has a non-
operational compressor
A crankcase heater is often used to A
prevent refrigerant from mixing with Low ambient temperature
compressor oil during periods of:
ALow ambient temperature
B High ambient temperature
C Low humidity
D High humidity
Leaks must be repaired on industrial C
process and refrigeration units with a 30%
50-pound charge or greater when
the annualized leak rate reaches _____
or more.
A 10%
B 20%
C 30%
D 40%
https://quizlet.com/1160809231/epa-608-type-2-practice-exam-complete-test-questions-and-answers-verified-answers-latest-update-2026-update-flas… 2/10