Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

MASTER ELECTRICIAN EXAM QUESTIONS WITH GUARANTEED ANSWERS [GUARANTEED ANSWERS]

Rating
-
Sold
-
Pages
20
Grade
A+
Uploaded on
26-03-2026
Written in
2025/2026

MASTER ELECTRICIAN EXAM QUESTIONS WITH GUARANTEED ANSWERS [GUARANTEED ANSWERS]

Institution
Indiana Master Electrician
Course
Indiana Master Electrician

Content preview

MASTER ELECTRICIAN EXAM QUESTIONS
WITH GUARANTEED ANSWERS
[GUARANTEED ANSWERS]
branch circuit - Correct Answers -That portion of a wiring system extending beyond the final
overcurrent device is called the:



Calculated load - Correct Answers -The final sum of the computed loads, based on the minimum
code requirements, is the



Resistance - Correct Answers -As compared to #10, a #8 wire of the same Iength has less:



0.001 inch - Correct Answers -One circular mil is the area of a circle whose diameter is:



1,000,000 cm - Correct Answers -A round bus-bar one inch in diameter, has a circular mil area
of:



four times as great - Correct Answers -A copper wire with twice the diameter of another wire
has a current carrying capacity:



10.4 - Correct Answers -The specific resistance of copper wire @ 20° C in ohms per circular mil
ft. is



permit current to flow - Correct Answers -Conductance of an electric circuit is that property that
will:



1O ohms - Correct Answers -The equivalent value of 0.1 mho is



directly proportional to its length - Correct Answers -The resistance of copper wire is:

,Feeder - Correct Answers -The portion of a wiring system between a point of distribution and
the branch circuit overcurrent device is



locking - Correct Answers -GFCI protection at a carnival is not required for equipment at circuit if
the receptacle is of the ____________type



not less than 1 1/4 in. from - Correct Answers -Where cables or nonmetallic raceways are
installed through bored.holes in joists, rafters, or wood members;holes shall be bored so that
the edge of the hole is the nearest edge -of the wood member.



located on a balcony accessible only to qualified persons

located in a room only accessible to

qualified persons

elevated 8 ft or more above floor or other working surface - Correct Answers -To guard live parts
over 50V but less than 600V, equipment is permitted to be



12Ft - Correct Answers -Overhead feeder conductors shall have a minimum __________ vertical
clearance over residential property and driveways, as well as those commercial areas not
subject to truck traffic, where the voltage is limited to 300 volts-to-ground.



36 inches - Correct Answers -Where rear access is required to work on de-energized parts on
the back of enclosed equipment, a minimum working space of horizontally shall be provided.



50' - Correct Answers -What is the maximum run length of a 18AWG fixture wire that is tapped
on to a 20 amp branch circuit?



power supply failure - Correct Answers -When the service disconnecting means is a power-
operated switch or circuit breaker, it shall be able to be opened by hand in the event of a

, 2 in of concrete - Correct Answers -Conductors are considered outside a buildings when they
are buried under not less than



8 - Correct Answers -In straight pull, the length of the box shall not be less than. ____times the
trade size of the largest raceway.



18" - Correct Answers -At least one receptacle outlet shall be installed within of the top of a
show window for each 12 linear feet measured horizontally across its length



1000A - Correct Answers -Ground-fault protection of equipment shall be provided fro solidly
grounded wye electrical services of more than 150 volts-to-ground, but not exceeding 600V
phase-to..phase for each service disconnecting means rated



18" - Correct Answers -Receptacle outlets in floors shall not be counted as part of the required

number of receptacle outlets unless located within ______ of the wall



50V - Correct Answers -Exposed live parts of motors and controllers operating at or more
between terminals shall be guarded against accidental contact by enclosure or by location



5' - Correct Answers -Lighting track shall not be installed less than______ above the finished
floor except' where protected from physical damage or where the track operates at less than 30
V rms, open-circuit voltage



4 - Correct Answers -Each general care area patient bed location shall be provided with a
minimum of_______receptacles, which can be single, duplex, or a combination with each
duplex counting as two receptacles



Combination Range hood/ Microwave

Written for

Institution
Indiana Master Electrician
Course
Indiana Master Electrician

Document information

Uploaded on
March 26, 2026
Number of pages
20
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$12.89
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
Pulseprep

Get to know the seller

Seller avatar
Pulseprep stuvia
Follow You need to be logged in order to follow users or courses
Sold
-
Member since
3 months
Number of followers
0
Documents
147
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions