EXAM
300 QUESTIONS AND CORECT DETAILED ANSWERS (VERIFIED
ANSWERS)
Study online at https://quizlet.com/_fuqlej
1. Which agency approves a a.) The Regional Water Quality Board site-specific
variance which CCR Title 23, Sec 2681(a) allows for an alternative method
of construction or
monitoring:
a.) The Regional Water Quality
Board
b.) The State Water Resources
Control Board
c.) The Department of Toxic
Substance Control
d.) The local agency
2. The regulations to enforce b.) California Code of Regulations; Title 23,
compliance of underground Chapter 16
storage tank systems in the state
are found in?
a.) Code of Federal Regula-tions,
40 CFR Part 281
b.) California Code of Regula-
tions, Title 23, Chapter 16
c.) Code of Federal Regula-tions,
40 CFR Part 280
d.) California Code of Regula-
tions, Title 23, Chapter 17
3. By definition an "underground b.) The tank, all connected piping, ancillary
storage tank system" in- equipment and containment system
cludes
a.) The tank, all connected pip-
(H&SC, Sec 25281(z)) ing and
dispensers
b.) The tank, all connected pip-
ing, ancillary equipment and
, ICC CALIFORNIA UST INSPECTOR EXAM NEWEST 2024 ACTUAL
EXAM
300 QUESTIONS AND CORECT DETAILED ANSWERS (VERIFIED
ANSWERS)
Study online at https://quizlet.com/_fuqlej
containment system c.) Only
the tank
d.) Only tanks totally beneath the
surface of the ground
4. The written report submitted b.) Cause of the release to the local agency after
an CCR Title 23, Sec 2652(c) unauthorized release is required to include the
following except:
a.) Description of actions tak-en
to stop the release
b.) Cause of the release
c.) Method of disposal of re-
leased product
d.) Date on which the release was
discovered
5. An unauthorized release D. All of the above which does not escape from
H&SC, Sec 25294 secondary containment only requires a record on the
operator's monitoring reports pro-
vided:
A. It did not increase the haz-ard
of fire
B. It did not cause any deteri-
oration of the secondary
containment
C. It was cleaned up within 8
hours of detection
D. All of the above
6. The annual monitoring certifi- D. A person who meets the requirements of
cation may be performed by: both a and b
A. A person possessing the CCR Title 23,
Sec 2715(i) appropriate contractors licenses
, ICC CALIFORNIA UST INSPECTOR EXAM NEWEST 2024 ACTUAL
EXAM
300 QUESTIONS AND CORECT DETAILED ANSWERS (VERIFIED
ANSWERS)
Study online at https://quizlet.com/_fuqlej
B. An individual trained and certified by the
manufacturer of the monitoring equipment C. A
designated UST operator
D. A person who meets the
requirements of both a and b
7. When an automatic tank c.) Outside air temperature gauge is utilized for sin-
CCR Title 23, Sec 2643(b)(1) gle-walled tank leak detection, it shall generate
a post-test hard copy data report of the following information, except: a.)
Liquid volume
b.) Fuel depth
c.) Outside air temperature
d.) Time and date of test
8. If a UST system is utilizing an c.) 90% overfill alarm, the alarm must be
triggered to alert the transfer operator when the tank is no more than
___________ full
a.) 85%
b.) 95%
c.) 90%
d.) 80%
9. An automatic tank gauge is a.) Tank utilized for leak detection of CCR Title
23, Sec 2643(b)(1) the ______________. a.) Tank
b.) Tank and Piping
c.) Piping
d.) Interstitial space
10. After completion of en- d.) To both the SWRCB and the local hanced leak
detection (ELD) agency
test, the ELD test results CCR Title 23, Sec 2644.1(a)(5) must be
submitted to the _________________. a.) The local agency
b.) The SWRCB
, ICC CALIFORNIA UST INSPECTOR EXAM NEWEST 2024 ACTUAL
EXAM
300 QUESTIONS AND CORECT DETAILED ANSWERS (VERIFIED
ANSWERS)
Study online at https://quizlet.com/_fuqlej
c.) Owner of the UST system
d.) To both the SWRCB and the
local agency
11. A permit to operate a UST sys- b.) Name of the tank manufacturer and tank
tem must have all of the fol- capacity lowing listed on the permit, CCR Title
23, Sec 2712(c) EXCEPT:
a.) The state UST identifica-tion
number(s)
b.) Name of the tank manufac-
turer and tank capacity
c.) Permit expiration date
d.) Monitoring requirements
12. A temporary closure is appro- b.) The UST system has ceased to store priate
for which of the follow- hazardous materials but will be used within
ing: the next 12 consecutive months
a.) The UST system is empty CCR
Title 23, Sec 2671 & 2670 and
will be removed from service
indefinitely
b.) The UST system has ceased to
store hazardous materials but
will be used
within the next 12 consecutive
months
c.) The UST system is unable to
meet compliance
requirements and will be
removed
d.) The UST system has been red-
tagged