NYC Modular Housing Contractor
License Exam Practice Questions
And Correct Answers (Verified
Answers) Plus Rationales 2026 Q&A
| Instant Download Pdf
1. Which of the following is the primary building code governing
modular housing in New York City?
A. International Residential Code (IRC)
B. New York City Building Code (NYCBC)
C. National Modular Housing Code (NMHC)
D. International Building Code (IBC)
Rationale: NYC modular housing must comply with the New
York City Building Code, which governs all construction
standards within the city.
https://www.stuvia.com/user/nursecare
,https://www.stuvia.com/user/nursecare
2. Modular units must be constructed to withstand transportation
stresses. What is the minimum design requirement for wind load?
A. 20 mph
B. 90 mph
C. 60 mph
D. 30 mph
Rationale: NYC Building Code requires modular units to
withstand a minimum wind load of 90 mph to ensure structural
integrity during transit and installation.
3. Who is responsible for ensuring that all modular construction
complies with NYC code before installation?
A. Modular manufacturer only
B. General contractor only
C. Licensed modular housing contractor
D. Building inspector
Rationale: The licensed modular housing contractor is
responsible for compliance with NYC codes, including
verification of manufacturer compliance before installation.
4. What is the maximum allowable height for a modular unit
without additional structural reinforcement?
A. One story
B. Three stories
C. Five stories
https://www.stuvia.com/user/nursecare
,https://www.stuvia.com/user/nursecare
D. Two stories
Rationale: Standard modular units in NYC can be stacked up to
three stories; beyond this, additional structural engineering and
reinforcement are required.
5. During site preparation, which of the following is a critical step?
A. Painting the modular unit off-site
B. Ensuring a level and compacted foundation
C. Installing interior finishes
D. Ordering furniture
Rationale: A level and compacted foundation is critical to ensure
proper placement, stability, and compliance with code before
modular units are set.
6. Which of the following best describes “HUD Code” homes?
A. Modular units built exclusively for commercial projects
B. Prefabricated homes that do not meet NYC standards
C. Manufactured homes regulated by the U.S. Department
of Housing and Urban Development
D. Temporary housing units for construction sites
Rationale: HUD Code homes are regulated federally but modular
homes in NYC must meet the stricter NYC Building Code.
7. What is the required fire-resistance rating for walls
separating modular units?
A. 15 minutes
https://www.stuvia.com/user/nursecare
, https://www.stuvia.com/user/nursecare
B. 30 minutes
C. 1 hour
D. 2 hours
Rationale: NYC Building Code requires a minimum 1-hour fire-
resistance rating for walls between modular units to prevent fire
spread.
8. Which document must a modular contractor submit to NYC
DOB before placing a modular building on site?
A. Certificate of occupancy only
B. Zoning permit only
C. Construction permit and DOB-approved plans
D. Warranty certificate
Rationale: Contractors must submit construction permits and
DOB- approved plans to ensure legal and code-compliant
installation of modular units.
9. In modular construction, what is the purpose of a crane mat?
A. To decorate the site
B. To store tools
C. To distribute weight and protect the ground during
crane operations
D. To connect modules
Rationale: Crane mats provide a stable base, distribute weight, and
https://www.stuvia.com/user/nursecare