This document contains questions and 100% verified error-free answers for the EPA Section 608 Certification covering Type I, Type II, and Type III. It includes topics such as refrigerant handling, leak detection, recovery and recycling procedures, environmental safety, and regulatory compliance. The material is designed to support thorough exam preparation and mastery of all Type I–III certification requirements.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

EPA SECTION 608 TYPE I, TYPE II , TYPE III || ERROR-
FREE ANSWERS 100%.

What is typically used on small appliances as a service aperture or other device for adding or
removing refrigerant?
a. A straight piece of tubing that is entered using a piercing access tube.
b. A line located 15 inches below the compressor.
c. A valve installed at the factory which has a ¼ inch diameter and machine threads.
d. A service aperture is not present because small appliances are exempt from this requirement.
correct answers a. A straight piece of tubing that is entered using a piercing access tube.


What type of appliances are technicians certified to service after passing the type 1 examination?
a. Appliances containing 5 pounds or less of refrigerant that have been hermetically sealed and
charged at the factory.
b. Split systems containing 5 pounds or less of refrigerant that have been hermetically sealed and
charged at the factory.
c. Appliances containing 5 pounds or less of refrigerant that have an open drive compressor and
have been charged at the factory.
d. Motor vehicle air conditioning equipment. correct answers a. Appliances containing 5 pounds
or less of refrigerant that have been hermetically sealed and charged at the factory.


What type of certification is required for persons recovering CFC's, HCFCs, or HFCs during
maintenance, service, or repair of small appliances.
a. Type II technician.
b. Type III technician.
c. Type I technician.
d. Technician who has passed the core exam. correct answers c. Type I technician.

,EPA Section 608 rules require capture of 80% of the HCFC and HFCs from a small appliance
sealed systems with a non-operating compressor if technicians are using;
a. a system-dependent (passive) process.
b. a self-contained (active) process.
c. either a passive or an active recovery process.
d. neither recovery process. correct answers c. either a passive or an active recovery process.


Which of the following does NOT meet the criteria for Type 1 appliance certification?
a. A MVAC-like system that holds three pounds of R-12.
b. a water cooler that holds 13 ounces of R-22
c. a food freezer that holds 22 ounces of R-134a
d. A dehumidifier that holds seven ounces of R-410A correct answers a. A MVAC-like system
that holds three pounds of R-12.


What of the following are included in EPA's definition of "small appliance?"
a. Products fully manufactured, charged, and hermetically sealed in a factory.
b. Products having 15 pounds or less of refrigerant.
c. Products with compressors under ½ horsepower.
d. Fully charged components ready for installation in a split system. correct answers a. Products
fully manufactured, charged, and hermetically sealed in a factory.


Which of the following is an approved substitute refrigerant for new household refrigerators,
freezers, and combination refrigeration/freezers?
a. R-600a
b. R-1234yf
c. R-1234zd
d. R-170 correct answers a. R-600a

,Which hydrocarbon refrigerant is approved for retrofit into existing household refrigerators?
a. HC R-600a 2 ounces or less
b. Blended HC R-441A
c. HC R-290 1 lb. or less
d. Hydrocarbons are not approved for retrofit applications correct answers d. Hydrocarbons are
not approved for retrofit applications


Recovery devices for use with small appliances containing CFCs, HCFCs, and HFCs must meet
which of the following requirements?
a. Recovering 90% of the refrigerant when the compressor is operating or achieving a 4-inch
vacuum
under the conditions of AHRI 740.
b. Recovering 80% of the refrigerant when the compressor is operating.
c. Recovering 95% of the refrigerant when the compressor is operating or achieving a 10-inch
vacuum
under the conditions of AHRI 740.
d. Recovering 75% of the refrigerant when the compressor is operating. correct answers a.
Recovering 90% of the refrigerant when the compressor is operating or achieving a 4-inch
vacuum under the conditions of AHRI 740.


What is the approximate pressure of a storage cylinder of recovered R-134a that does not contain
any non-condensable impurities and is stored in a room where the temperature is 80°F?
a. 37 psig
b. 87 psig
c. 157 psig
d. 207 psig correct answers b. 87 psig


Before beginning a refrigerant recovery procedure, it is ALWAYS necessary to;
a. allow the appliance to stabilize at room temperature.

, b. know the type of refrigerant that is in the system.
c. remove the appliance to an outdoor location.
d. disconnect the appliance from its power source. correct answers b. know the type of
refrigerant that is in the system.


A passive system-dependent recovery process for small appliances;
a. still uses a pump to recover refrigerant.
b. must use a pressure relief device when recovering refrigerant.
c. captures refrigerant in a non-pressurized container.
d. can only be performed on a system with an operating compressor. correct answers c. captures
refrigerant in a non-pressurized container.


For which of the following refrigeration systems/appliances would it be permissible to use a
passive recovery device for recovery of CFCs, HCFCs, and HFCs?
a. A centrifugal air conditioner
b. A reciprocating liquid chiller
c. A single compressor large commercial walk-in freezer
d. A domestic refrigerator correct answers d. A domestic refrigerator


What is the maximum normal charge of HCFC or HFC refrigerant in an appliance that is allowed
to use system dependent recovery equipment?
a. 5 pounds
b. 10 pounds
c. 15 pounds
d. 50 pounds correct answers c. 15 pounds


What is the maximum allowable factory charge of refrigerant for Type I appliances using CFCs,
HCFCs, or HFCs?
a. 3 pounds

Geschreven voor

Vak

Documentinformatie

Geüpload op
28 maart 2026
Aantal pagina's
49
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
TESTBANKSSTORES
4.0
(1)

Maak kennis met de verkoper

Seller avatar
TESTBANKSSTORES Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
9
Lid sinds
8 maanden
Aantal volgers
1
Documenten
1397
Laatst verkocht
3 weken geleden
TESTBANKSSTORES

Accounting, Finance, Statistics, Computer Science, Nursing, Chemistry, Biology & More — A+ Test Banks, Study Guides & Solutions As a Top 1st Seller on Stuvia and a nursing professional, my mission is to be your light in the dark during nursing school and beyond. I know how stressful exams and assignments can be, which is why I’ve created clear, reliable, and well-structured resources to help you succeed. I offer test banks, study guides, and solution manuals for all subjects — including specialized test banks and solution manuals for business books. My materials have already supported countless students in achieving higher grades, and I want them to be the guide that makes your academic journey easier too. I’m passionate, approachable, and always focused on quality — because I believe every student deserves the chance to excel. **Ace Your Exams with Confidence!**

Lees meer Lees minder
4.0

1 beoordelingen

5
0
4
1
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen