Which of the following can be avoided by proper use of a
automatic injector pressure limit control?
1. Vessel damage
2. catheter whipping
2. catheter breakage
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1,2, and 3 - Answer-Proper use of an automatic injector
pressure control avoids vessel damage, catheter
whipping, and catheter damage.
Which of the following are the functions of a digital image
processor?
1. digitizing television frames
2. displaying digital images
3. storing digital images
,2|Page
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1, 2, and 3 - Answer-A digital processor digitizes
television frames and stores, displays, and manipulates
them.
What effect does the addition of side holes in a catheter
have on the total flow rate?
A. 10 to 20 percent increase
B. 50 to 60 percent increase
C. 10 to 20 percent decrease
D. 50 to 60 percent decrease - Answer-The addition of
side holes in a catheter will increase the flow rate to 10 to
20 percent.
What is the area relationship indicated by the power factor
of an automated injector?
1. power cylinder
2. catheter
3. syringe
A. 1 and 2 only
,3|Page
B. 1 and 3 only
C. 2 and 3 only
D. 1, 2, and 3 - Answer-The power factor of an automatic
power injector indicates the area relationship of the power
cylinder to the syringe
How long is the injection time for 12ml of contrast media
delivered at 2.5 ml/sec?
A. 0.2 sec
B. 2.5 sec
C. 4.8 sec
D. 30 sec - Answer-Answer: C
Injection time is calculated as volume/time, so 12/2.5
equals 4.8 seconds
Which of the following describe exact framing of a
fluoroscopic image in a Cine film system?
1. the circular image intensifier image is included within
the square film frame.
2. the diameter of the intensifier image is equal to the
mean of the transverse dimensions of the useful square
film area.
, 4|Page
3. The diameter of the intensifier image is equal to the
diagonal dimensions of the useful square film area.
A. 1 only
B. 2 only
C. 3 only
D. 1,2, and 3 - Answer-Answer: A
Exact framing of a fluoroscopic image for Cine film
recording includes the entire fluoroscopic with the circular
image within the square film frame
What is angiography?
A. radiographic exam of veins
B. radiographic exam of arteries
C. radiographic exam of vessels
D. the study of vascular flow patterns - Answer-Answer : C
What term describes a guide wire in which position of the
inside portion can be varied?
A. J guide wire
B. straight guide wire
C. fixed core
D. moveable core - Answer-D