ARCH 333 FINAL EXAM 2026
ACTUAL QUESTIONS WITH
VERIFIED ANSWERS.
Examples of INTERNALLY dominated building types: - correct
answer--large office and school buildings
-auditoriums
-theaters
-factories
Lafayette''s latitude is... - correct answer-30 degrees
what is the altitude of the sun for Lafayette at noon on the
equinox: - correct answer-60 degrees
A= 90-L
Preparations:
[plumbing sequence] - correct answer-below grade, piping is
installed and capped BEFORE placing concrete or setting floor
joists
, Page | 2
other preparations
[plumbing sequence] - correct answer--water test done,
subjecting the system to 10 ft of hydrostatic pressure for at
least 15 minutes
-pipes are set at a slope of 1/8" to 1/4" per foot to properly drain
-water lines are set below frost line
Rough In
[plumbing sequence] - correct answer--when the roof deck and
wall heating are complete the plumbing crew "roughs" for
fixtures
-water supply pipes and drainage pipes are stubbed at the
proper height for the individual fixtures and the Vent Stacks are
completed through the roof
-piping is then LEAK TESTED before building insulation and
sheetrock work begins
Rough In