ICC Vapor Recovery 1 | QUESTIONS AND
ANSWERS | LATEST UPDATE
Save
Terms in this set (60)
Which of the following is not d. shear valve
considered "hanging hardware"?
a. nozzle
b. swivel
c. whip hose
d. shear valve
Per Executive Order. VR-201-E, if the B. 60
dispensing vacuum of the Healy VP-
1000 pump is below ____ inches of WC,
the dispenser should be removed
from service.
A. 50
B. 60
C. 75
D. 100
,In a coaxial hose for a balance B. the inner hose
system, the product flows through
the ____?
A. the belllows
B. the inner hose
C. the outer hose
D. both hoses
Per the Vapor Recovery Equipment B. proper installation
Defects List (VRED), the ____ of any
component required to be used by
the system's EO. Is not considered a
defect.
A. absence
B. proper installation
C. disconnection
D. improper installation
The three elements in a fire triangle C. fuel, oxygen, & ignition source
are ____?
A. oxygen, fuel, & LEL
B. fuel, fire, & carbon dioxide
C. fuel, oxygen, & ignition source
D. ignition source, carbon dioxide, &
fuel
, According to PEI RP-300, a D. detect vapor leaks in the vapor recovery system
combustible gas indicator is used to?
A. determine carbon dioxide levels
B. monitor benzene, toluene, & ethyl
benzene levels
C. determine the (UEL) upper
explosion limit of gasoline
D. detect vapor leaks in the vapor
recovery system
Per CP-201, liquid traps in the A. Not allowed
dispenser vapor piping are:
A. Not allowed
B. Allowed only with an assist system
C. Allowed if approved by CARB
D. Allowed when hoses with liquid
removal systems are used
E. detect vapor leaks in the vapor
recovery system
Which of the following is not an B. spill-bucket
overfill device?
A. ball-float
B. spill-bucket
C. tank overfill alarm
D. drop-tube flapper valve
ANSWERS | LATEST UPDATE
Save
Terms in this set (60)
Which of the following is not d. shear valve
considered "hanging hardware"?
a. nozzle
b. swivel
c. whip hose
d. shear valve
Per Executive Order. VR-201-E, if the B. 60
dispensing vacuum of the Healy VP-
1000 pump is below ____ inches of WC,
the dispenser should be removed
from service.
A. 50
B. 60
C. 75
D. 100
,In a coaxial hose for a balance B. the inner hose
system, the product flows through
the ____?
A. the belllows
B. the inner hose
C. the outer hose
D. both hoses
Per the Vapor Recovery Equipment B. proper installation
Defects List (VRED), the ____ of any
component required to be used by
the system's EO. Is not considered a
defect.
A. absence
B. proper installation
C. disconnection
D. improper installation
The three elements in a fire triangle C. fuel, oxygen, & ignition source
are ____?
A. oxygen, fuel, & LEL
B. fuel, fire, & carbon dioxide
C. fuel, oxygen, & ignition source
D. ignition source, carbon dioxide, &
fuel
, According to PEI RP-300, a D. detect vapor leaks in the vapor recovery system
combustible gas indicator is used to?
A. determine carbon dioxide levels
B. monitor benzene, toluene, & ethyl
benzene levels
C. determine the (UEL) upper
explosion limit of gasoline
D. detect vapor leaks in the vapor
recovery system
Per CP-201, liquid traps in the A. Not allowed
dispenser vapor piping are:
A. Not allowed
B. Allowed only with an assist system
C. Allowed if approved by CARB
D. Allowed when hoses with liquid
removal systems are used
E. detect vapor leaks in the vapor
recovery system
Which of the following is not an B. spill-bucket
overfill device?
A. ball-float
B. spill-bucket
C. tank overfill alarm
D. drop-tube flapper valve