Questions and Answers
1.Protruding objects may not protrude more than inches into the path of
travel.
Answer 4"
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 15
2.In new buildings, thresholds at doorways should be no higher than .-
Answer 1/2"
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 30
3.In a Type A unit, if measuring to the highest part of the rim or highest part
of the counter, what is the maximum height of the sink front above the
floor?
Answer 34"
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 149
1/
69
,4.The height of handrails shall be minimum and maximum
vertically above stair nosings, ramp and walking surfaces.
Answer 34" minimum, 38" maximum
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 62
5.A hallway more than 24 inches long must have a clear width of .
Answer 36"
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 19
6.Enter and proceed" is presented as a on the raised touchable
surface on a function key."
Answer Circle
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 107
7.Operable parts shall be operable with one hand and shall not require
Answer Tight grasping, pinching, or twisting of the wrist.
ANSI Accessible and Usable Buildings and Facilities,
2/
69
,2017 Page 18
8.In existing buildings and facilities, the clear width of a walking surface
shall be permitted to be reduced to minimum for a length of 24
inches maximum.
Answer 32 inches
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 19
9.The clear width of an exterior accessible route located within seating
areas shall be minimum.
Answer 36 inches
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 19
10.The running slope of walking surfaces shall not be steeper than
Answer 1:20
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 19
11. What components shall not be part of an accessible route?
Answer Revolving doors & Turnstiles
3/
69
, ANSI Accessible and Usable Buildings and Facilities,
2017 Page 19
12.The maximum height of existing elevator call buttons shall be permitted
to be located above the floor.
Answer 54"
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 40
13.The maximum knee clearance shall be permitted to extend under an
element that is 9" above the floor.
Answer 25"
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 13
14.The brightness of the elevator car landing sill, threshold, platform
and controls are to be no less than foot candles.
Answer 5
ANSI Accessible and Usable Buildings and Facilities,
2017 Page 51
4/