A yellow insulated copper tracer wire or other approved
conductor shall be installed ____ to the underground
nonmetallic gas piping. - Answer-Adjacent-404.15.3 tracer
The floor register of a floor furnace is permitted to be
installed ____ - Answer-12 inches from the draperies-
609.2 #3 placement
Casing extension boots shall not be installed on a wall
furnace unless __ - Answer-listed as a part of the
appliance.-608.5 ducts prohibited
Outside ventilation air shall be supplied to the space
containing a recirculating direct fired industrial heater at a
minimum rate of _ com per 1,000 but/h of the rated input
of the heater. - Answer-4-612.5 air supply
,2|Page
Clothes dryer exhaust ducts shall be equipped with a ___ -
Answer-backdraft damper- 614.4 exhaust installation
Vented wall furnaces shall be located so as not to cause a
___ to walls floors combustible furnishings or doors. -
Answer-fire hazard- 608.3 location
Non recirculating direct fired industrial air heaters shall not
be used to supply any area containing ___ - Answer-
sleeping quarters-611.2 installation
dryer exhaust systems shall be independent of all other
systems and shall convey the moisture and any products
of combustion to the - Answer-outside of the building
614.1 installation
dryer ducts shall not be connected or installed with ___ or
other fasteners that will obstruct the flow. - Answer-sheet
metal screws 614.4 exhaust installation
where space for a domestic clothes dryer is provided an
______ system shall be installed - Answer-exhaust duct
614.6.7 exhaust duct required
,3|Page
the minimum unobstructed total area of the outside and
return air ducts or openings to a forced air warm air
furnace shall be not less than __ square inches per 1,000
btu/h output rating capacity of the furnace - Answer-2-
618.2 forced air furnaces
in general return air for a forced air furnace shall not be
taken from a ____ - Answer-Crawl space-618.5 #7
prohibited sources
the required ventilation opening to a sauna room shall not
be less than _ inches by _ inches - Answer-4 and 8- 615.7
sauna room
suana heaters shall be equipped with a thermostat that
limits the room temp to no more than ___ degrees
Fahrenheit - Answer-194 degrees-615.6 heat and time
controls
The ____ shall be responsible for the maintenance of fuel
gas installations. - Answer-owner or owner agents- 102.3
Maintenance
, 4|Page
If the permit has not been issued, an application for a
permit is considered abandoned _____ days after the date
of filing. - Answer-180 days-106.3.2 Time limitation of
application
The lowest portion of a floor furnace shall have 12 inch
minimum clearance on all sides except the control side,
which shall have a ____ minimum clearance. - Answer-18-
609.4 Clearance
Water heaters utilized both to supply potable water and
provide hot water for space heating shall be listed and
labeled and shall be installed in accordance with the
_____. - Answer-I.P.C. International Plumbing code- 624.2
Water heaters used for space heating
A drip shall not be be located where condensate is subject
to ____. - Answer-Freezing-408.3 Location of drips
A means to interrupt the electrical supply to an air
conditioning appliance shall be provided ____ and not
more than ___ feet from the air conditioner. - Answer-
Within Sight and 50 feet- 627.10 switches in electrical
supply