When installed horizontally, 11/4-inch polypropylene pipe and tubing shall be supported at
maximum intervals of __________.
a. 32 inches
b. 48 inches
c. 8 feet
d. 10 feet
Reference __________ - ANS✔✔ b Table 308.5
A horizontal 4-inch PVC drainage pipe suspended from the ceiling requires ________ at a 90
degree turn.
a. axial restraints
b. sway bracing
c. coupling restraints
d. thrust blocks
Reference __________ - ANS✔✔ b Sec. 308.6
One-half-inch CPVC water pipe installed horizontally shall be supported at maximum intervals of
__________ feet.
a. 6
b. 5
c. 4
d. 3
Reference __________ - ANS✔✔ d Table 308.5
, Support hangers for 10-foot lengths of cast-iron soil pipe suspended from a ceiling shall be
spaced not more than __________ feet.
a. 2.5
b. 5
c. 7.5
d. 10
Reference __________ - ANS✔✔ d Table 308.5, Footnote a
PVC pipe installed vertically requires a guide installed midway between required supports for
pipe sizes __________ inch(es) and smaller.
a. 1
b. 3
c. 2
d. 11/4
Reference __________ - ANS✔✔ c Table 308.5, Footnote b
Which of the following is not specifically allowed for sealing around a pipe that passes through
an exterior wall?
a. flashing
b. caulk
c. foam sealant
d. gasketing system
Reference __________ - ANS✔✔ a Sec. 315.1
When located in a flood hazard area, the top of a potable water well casing without a sealed
cover shall extend not less than __________ inches above the design flood elevation.