1. What is the primary purpose of a boiler inspection?
o o o o o o o o
A. Improve fuel efficiency o o
B. Assess operator performance
o o
C. Ensure the safe operation of the boiler
o o o o o o
D. Reduce water usage o o
The main goal of inspection is to prevent hazardous conditions and
o o o o o o o o o o
oensure the boiler operates safely.
o o o o
2. According to Texas regulations, how often must high-pressure boilers
o o o o o o o o
obe inspected internally?
o o
A. Every 6 months o o
B. Annually
C. Every 2 years o o
D. Every 3 years o o
High-pressure steam boilers require internal inspections at least once
o o o o o o o o
oper year.
o
,3. What document establishes the rules for the construction of new
o o o o o o o o o
boilers?
o
A. ASME Section II o o
B. NFPA 85 o
C. ASME Boiler and Pressure Vessel Code Section I
o o o o o o o
D. API 510 o
ASME Section I outlines construction requirements for power boilers.
o o o o o o o o
4. What type of test is typically conducted to verify the integrity of a
o o o o o o o o o o o o
repaired pressure boundary?
o o o
A. Ultrasonic Test o
B. Radiographic Test o
C. Hydrostatic Test o
D. Magnetic Particle Test o o
Hydrostatic tests are standard for pressure boundary integrity
o o o o o o o
verification after repairs.
o o o
5. Which device prevents overpressure in a boiler?
o o o o o o
A. Water level gauge o o
B. Blowdown valve o
C. Safety valve o
D. Economizer
Safety valves release steam to maintain pressure within safe limits.
o o o o o o o o o
6. What is the minimum size of a safety valve discharge outlet for a 200
o o o o o o o o o o o o o
psi power boiler?
o o o
A. 1 inch
o
B. 2.5 inches
o
C. 3 inches
o
D. 4 inches
o
Discharge sizes are regulated based on pressure and capacity per
o o o o o o o o o
ASME standards.
o o
, 7. Which of the following is not a type of non-destructive examination
o o o o o o o o o o
(NDE)?
o
A. Radiographic testing o
B. Magnetic particle testing o o
C. Ultrasonic testing o
D. Destructive bend testing o o
Destructive tests are not NDE since they damage the component
o o o o o o o o o
being tested.
o o
8. What should be checked before performing a hydrostatic test?
o o o o o o o o
A. Fuel line pressure
o o
B. Exhaust damper position o o
C. Temperature and pressure relief valve operation o o o o o
D. Flame scanner alignment o o
All relief valves must be verified to avoid overpressurizing during the
o o o o o o o o o o
test.
o
9. What does the acronym “NB” stamp indicate?
o o o o o o
A. Non-boiler use o
B. National Board certification o o
C. National Bonding o
D. Nuclear Boiler code o o
The “NB” stamp is applied to pressure vessels registered with the
o o o o o o o o o o
National Board.
o o
10. What must an inspector do when they find a hazardous
o o o o o o o o o
condition on a boiler?
o o o o
A. Note it in the inspection report only
o o o o o o
B. Inform the operator to monitor it
o o o o o
C. Condemn or tag out the boiler o o o o o
D. Wait until the next inspection