Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NHIE Prep – HVAC Questions and Answers 100% Correct

Beoordeling
-
Verkocht
-
Pagina's
3
Cijfer
A+
Geüpload op
01-04-2026
Geschreven in
2025/2026

NHIE Prep – HVAC Questions and Answers 100% Correct The fill pipe for an underground oil tank is __ inches. 2 The duct size for a dryer vent is a minimum of __ inches. 4 __ feet is the maximum spacing between supports for horizontal non-metallic flex air ducts. 4 A furnace can be in a laundry room. T or F? True The hearth of a fireplace should extend __ inches in front if the opening is 6 feet, and __ inches in front if over 6 feet. 16, 20 There is a minimum __ inch separation between a chimney and combustibles. 2 Vents must terminate a minimum of 2 feet above and __ feet horizontal to a window or other opening. 10 Return ductwork is __% larger than supply ductwork. 30 A gas appliance vent through a roof requires a minimum clearance of __ feet. 2 AC condensate drain lines must be at least __ inches. 3/4 The minimum air gap on an evaporative cooler is __ inch(es). 1 A clothes dryer vent may pass through a ventilation duct. T or F? True Vent pipes shall not be less than ___ inches 1 1/4 Outside combustion air cannot be taken from an attic that has a height of less than __ inches. 30 Outdoor air shall not be taken from within 10 feet of an appliance or plumbing vent that is located less than 3 feet above the air inlet. T or F? True The minimum access opening for a gas meter is __x24 inches. 22 With an upright furnace in an attic, __ feet of headroom is required. 5 New furnaces (after Jan. 1992) must be at least __% efficient. 80 Workspace in front of a furnace must be __ inches deep in front. 30 It is alright to access a furnace through a broom closet, but it cannot be in a storage closet. T or F? True

Meer zien Lees minder
Instelling
Nhie
Vak
Nhie

Voorbeeld van de inhoud

NHIE Prep – HVAC Questions and
Answers 100% Correct

The fill pipe for an underground oil tank is __ inches. - answer2

The duct size for a dryer vent is a minimum of __ inches. - answer4

__ feet is the maximum spacing between supports for horizontal non-metallic flex air
ducts. - answer4

A furnace can be in a laundry room. T or F? - answerTrue

The hearth of a fireplace should extend __ inches in front if the opening is <6 feet, and
__ inches in front if over 6 feet. - answer16, 20

There is a minimum __ inch separation between a chimney and combustibles. -
answer2

Vents must terminate a minimum of 2 feet above and __ feet horizontal to a window or
other opening. - answer10

Return ductwork is __% larger than supply ductwork. - answer30

A gas appliance vent through a roof requires a minimum clearance of __ feet. - answer2

AC condensate drain lines must be at least __ inches. - answer3/4

The minimum air gap on an evaporative cooler is __ inch(es). - answer1

A clothes dryer vent may pass through a ventilation duct. T or F? - answerTrue

Vent pipes shall not be less than ___ inches - answer1 1/4

Outside combustion air cannot be taken from an attic that has a height of less than __
inches. - answer30

Outdoor air shall not be taken from within 10 feet of an appliance or plumbing vent that
is located less than 3 feet above the air inlet. T or F? - answerTrue

The minimum access opening for a gas meter is __x24 inches. - answer22

With an upright furnace in an attic, __ feet of headroom is required. - answer5

Geschreven voor

Instelling
Nhie
Vak
Nhie

Documentinformatie

Geüpload op
1 april 2026
Aantal pagina's
3
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$16.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
julianah420 Phoenix University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
696
Lid sinds
3 jaar
Aantal volgers
329
Documenten
35596
Laatst verkocht
3 dagen geleden
NURSING,TESTBANKS,ASSIGNMENT,AQA AND ALL REVISION MATERIALS

On this page, you find all documents, package deals, and flashcards offered by seller julianah420

4.2

155 beoordelingen

5
101
4
21
3
12
2
5
1
16

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen