Answers 100% Correct
The fill pipe for an underground oil tank is __ inches. - answer2
The duct size for a dryer vent is a minimum of __ inches. - answer4
__ feet is the maximum spacing between supports for horizontal non-metallic flex air
ducts. - answer4
A furnace can be in a laundry room. T or F? - answerTrue
The hearth of a fireplace should extend __ inches in front if the opening is <6 feet, and
__ inches in front if over 6 feet. - answer16, 20
There is a minimum __ inch separation between a chimney and combustibles. -
answer2
Vents must terminate a minimum of 2 feet above and __ feet horizontal to a window or
other opening. - answer10
Return ductwork is __% larger than supply ductwork. - answer30
A gas appliance vent through a roof requires a minimum clearance of __ feet. - answer2
AC condensate drain lines must be at least __ inches. - answer3/4
The minimum air gap on an evaporative cooler is __ inch(es). - answer1
A clothes dryer vent may pass through a ventilation duct. T or F? - answerTrue
Vent pipes shall not be less than ___ inches - answer1 1/4
Outside combustion air cannot be taken from an attic that has a height of less than __
inches. - answer30
Outdoor air shall not be taken from within 10 feet of an appliance or plumbing vent that
is located less than 3 feet above the air inlet. T or F? - answerTrue
The minimum access opening for a gas meter is __x24 inches. - answer22
With an upright furnace in an attic, __ feet of headroom is required. - answer5