THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND
TO DETERMINE QUALIFICATIONS. - ANSWERS--OWNER
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON
PREMISES FOR A MIN. OF __________ YEARS. - ANSWERS--3
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY
WITH REQUIREMENTS. - ANSWERS--IMPAIRMENT COORDINATOR
REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN
________ FLOOR(S) ARE CONSIDERED PLANNED REMOVAL FROM
SERVICE. - ANSWERS--1
SHUTDOWNS AFFECTING MORE THAN _________ FLOOR(S) ARE
CONSIDERED UNPLANNED OUT OF SERVICE CONDITIONS. - ANSWERS--
1
NOTIFICATION TO FDNY IS NOT REQUIRED, PROVIDED SYSTEM IS
RETURNED TO SERVICE WITHIN ______ HOURS. - ANSWERS--8
,2|Page
FOR UNPLANNED REMOVAL FROM SERVICE, THE COF HOLDER SHALL
IMMEDIATELY REPORT CONDITION TO THE ___________ AND THE FIRE
DEPT. - ANSWERS--OWNER OF THE BUILDING
IF A MINOR DEFECT IS OBSERVED, IT SHALL BE CORRECTED WITHIN
_________ DAYS OR IT WILL BE CONSIDERED AN IMPAIRMENT. -
ANSWERS--30
WHAT DOES "OOS" STAND FOR? - ANSWERS--OUT OF SERVICE
OOS SYSTEMS SHALL BE IDENTIFIED BY PLACING ________ AT FIRE
DEPT. CONNECTIONS, SYS. CONTROL VALVES, AND FIRE COMMAND
CENTER - ANSWERS--TAGS
A _______ SHALL BE REQUIRED TO POST TAGS AT MAIN CONTROL
VALVE AND ANY SECTIONAL VALVES. - ANSWERS--MASTER FIRE
SUPPRESSION PIPING CONTRACTOR
__________ SHALL BE POSTED ON THE TAG INDICATING BOTH STATIC
AND FLOW PRESSURES BEFORE AND AFTER. - ANSWERS--DRAIN TEST
RESULTS
GREEN TAGS INDICATE THAT __________. - ANSWERS--NO
IMPAIRMENT WAS FOUND
,3|Page
GREEN TAGS WILL BE PLACED ON THE ____________. - ANSWERS--
MAIN CONTROL VALVE
SYSTEMS PARTIALLY OR FULLY OUT OF SERVICE SHALL HAVE A
____________ TAG PLACED ON THE MAIN CONTROL VALVE. -
ANSWERS--RED
A _________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS
TO INDICATE THE SYSTEM IS FULLY OUT OF SERVICE. - ANSWERS--
WHITE
A ________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS
TO INDICATE THE SYSTEM IS PARTIALLY OUT OF SERVICE. - ANSWERS--
BLUE
THE IMPAIRMENT COORDINATOR WILL NOTIFY THE ___________
CARRIER, CENTRAL STATION AND OCCUPANTS. - ANSWERS--
INSURANCE
PRIOR TO RETURNING A SYS. TO SERVICE, THE ___________ SHALL
ENSURE THAT NECESSARY TESTS AND INSPECTIONS ARE CONDUCTED. -
ANSWERS--IMPAIRMENT COORDINATOR
, 4|Page
GLYCERIN NOT GREATER THAN _________ PERCENT OR GLYCOL NOT
GREATHER THAN ________ PERCENT SHALL BE USED TO PROTECT
FROM FREEZING. - ANSWERS--50, 40
THE COF NUMBER AND SIGNATURE OF COF HOLDER SHALL BE POSTED
NEAR THE ____________. - ANSWERS--MAIN CONTROL VALVE
__________ SHALL BE READILY AVAILABLE TO ANY REPRESENTATIVE OF
THE FIRE DEPT. THESE ARE TO BE MAINTAINED ON SITE FOR 3 YEARS. -
ANSWERS--RECORDS
FAILURE TO MAKE INSPECTIONS MAY RESULT IN __________ OF THE
COF AND COURT PROCEEDINGS. - ANSWERS--REVOCATION
THE COF HOLDER MAY INSPECT, TEST, AND PERFORM ROUTINE MX IF
THEY HOLD THE FOLLOWING CERTS: - ANSWERS--REFRIGERATION
OPERATING ENGINEER, HIGH PRESSURE OPERATING ENGINEER, AND
NYS HIGH PRESSURE OPERATING ENGINEER.
A ________ CAN INSPECT, MAINTAIN, TEST, AND REPAIR ALL FIRE
STANDPIPE AND SPRINKLER SYSTEMS. - ANSWERS--MASTER FIRE
SUPPRESSION PIPING CONTRACTOR (MFSPC)
A MASTER PLUMBER (MP) WITH COF IS LIMITED TO RESIDENTIAL
OCCUPANCIES WITH _________ SPRINKLER HEADS OR LESS. -
ANSWERS--30