1) Fuel gas or oxygen containers in storage must be separated from any
combustible materials by a minimum distance of - ANSWER ✓ 20 feet.
2) Most fires are the result of - ANSWER ✓ Sparks.
3) Sparks and pieces of hot metal are the source of ignition in about______ of
fires in industrial occupancies. - ANSWER ✓ 60.
4) Under no circumstances can hot work be performed within _____ feet of
flammable or explosive materials. - ANSWER ✓ 35.
5) If torch operation is to be discontinued for a period of ___________, the
torch valve must be closed and the gas supply to the torch must be
completely shut. - ANSWER ✓ One hour or more.
6) A torch should be ignited by using a - ANSWER ✓ Friction device.
7) Why should oil or grease not be used near oxygen? - ANSWER ✓ It might
cause an explosion.
8) How long is a site permanent specific permit to store flammable gases valid
for? - ANSWER ✓ 30 days
9) How many Fire Guards are required on a job site that has 3 torches in
operation? - ANSWER ✓ One per torch and additional one stationed on the
floor below.
, 10) Portable LPG containers greater than ______ must not be stored in
residential occupancies. - ANSWER ✓ 16.4 oz.
11) An oxygen cylinder may store gas at pressure up to - ANSWER ✓
2200 psi.
12) A Responsible Person is one who is - ANSWER ✓ trained in the fire
safety hazards associated with hot work, and in the necessary and
appropriate measures to minimize those hazards, who is designated by the
owner of a premises to authorize the performance of hot work at the
premises.
13) A designated Hot Work area must be at least_______ feet away from
combustible materials. - ANSWER ✓ 35.
14) For all Hot Work, inspections must be completed_______ after
completion of torch operations. - ANSWER ✓ 30 minutes.
15) A minimum ___________ rating Fire Extinguisher must be readily
accessible within ________ of the hot work location for torch operations. -
ANSWER ✓ 2-A:20-B:C, 30 feet.
16) For a Torch-applied Roof System, a minimum ___________ rating
Fire Extinguisher must be readily accessible within ________. - ANSWER
✓ 3-A: 40-B:C, 30 feet.
17) Empty compressed gas cylinders - ANSWER ✓ Should be handled in
the same manner as full ones.
18) Panic Bar - ANSWER ✓ A device fitted on the inside of a door that
would allow a person to push against a door to open it.
19) A type of valve typically used in sprinkler systems - ANSWER ✓ OS
& Y Valve- Outside Screw and Yoke Valve.
20) Fire Drill - ANSWER ✓ A training exercise by which building
occupants are familiarized with and/ or practice the procedures for the safe,
orderly and expeditious in-building relocation, partial evacuation or