COMPREHENSIVE SCRIPT 2026 QUESTIONS
AND ANSWERS GUARANTEED TO PASS
◉ 36 inches. Answer: Where rear access is required to work on de-
energized parts on the back of enclosed equipment, a minimum
working space of horizontally shall be provided.
◉ 50'. Answer: What is the maximum run length of a 18AWG fixture
wire that is tapped on to a 20 amp branch circuit?
◉ power supply failure. Answer: When the service disconnecting
means is a power-operated switch or circuit breaker, it shall be able
to be opened by hand in the event of a
◉ 2 in of concrete. Answer: Conductors are considered outside a
buildings when they are buried under not less than
◉ 8. Answer: In straight pull, the length of the box shall not be less
than. ____times the trade size of the largest raceway.
,◉ 18". Answer: At least one receptacle outlet shall be installed
within of the top of a show window for each 12 linear feet measured
horizontally across its length
◉ 1000A. Answer: Ground-fault protection of equipment shall be
provided fro solidly grounded wye electrical services of more than
150 volts-to-ground, but not exceeding 600V phase-to..phase for
each service disconnecting means rated
◉ 18". Answer: Receptacle outlets in floors shall not be counted as
part of the required
number of receptacle outlets unless located within ______ of the wall
◉ 50V. Answer: Exposed live parts of motors and controllers
operating at or more between terminals shall be guarded against
accidental contact by enclosure or by location
◉ 5'. Answer: Lighting track shall not be installed less than______
above the finished floor except' where protected from physical
damage or where the track operates at less than 30 V rms, open-
circuit voltage
◉ 4. Answer: Each general care area patient bed location shall be
provided with a minimum of_______receptacles, which can be single,
, duplex, or a combination with each duplex counting as two
receptacles
◉ Combination Range hood/ Microwave
oven. Answer: In a Dwelling Unit which appliance is allowed to have
a 24" cord with attachment ground plug?
◉ 1. Answer: At least_____ 125 V, single phase, 15 A or 20 A, duplex
with ground-fault circuit interrupter receptacle shall be provided in
each elevator machine room and elevator machinery space.
◉ 25A. Answer: Lighting systems covered by Article 411 shall have a
power supply rated not more than______and not more than 30V
◉ 90. Answer: Temporary electrical power and lighting installations
shall be permitted for a period not exceeding ____days for Christmas
decorative lighting and similar purposes
◉ 10'. Answer: Lighting systems operating at 30V or less shall not
be·installed within_______of pools, spas, fountains, or similar
locatipns
◉ 12 /40. Answer: Where communications wires and cables and
electric light or power conductors are supported by the same pole
and are run paralled to each other in span , the·supply service drops