QUESTIONS WITH SOLUTIONS GRADED A+
◉P100 engine specification. Answer: Yanmar L100AE/EE air cooled,
single cylinder, 4 stroke, diesel F-76 or JP-5
◉P100 Specifications. Answer: 164lbs of wet weight, 1.45 Gallons of
fuel 2.75 hrs of run time 100GPM@83PSI@20ft lift, packing screw
6" long 9/16 wrench, drip rate 5-50 DPM
◉Securing P100. Answer: turn speed to low, run with no load for
aprox 5 minutes to allow it to cool off
◉P6 Specs. Answer: Honda GX200, 6.5HP, 3Gal tank, 4hour run time,
86 octane gas,unit 60lbs, kit 120lbs
◉P6 Dry run time. Answer: This pump is equipped with a
mechanical lip seal. Avoid running the pump dry or at high speed if
there is no discharge water. If there is no discharge flow after two
minutes, shut down the engine and check for leaks in the suction
hose
, ◉P6 Maintenance. Answer: • Automotive 4 stroke SAE 10W-30
detergent oil is recommended for the engine for general operation.
See the Honda GX200 Engine Owner's Manual for oil
recommendations for adverse operating conditions. • Check the
engine oil level prior to each use. Add oil as necessary. • Change the
engine oil after the first 20 hours; then every 100 hours, or 6 months
thereafter. • Replace the inline fuel filter after the first 20 hours;
then every 100 hours, or 6 months thereafter.
◉P6 time between fuel tank changes. Answer: 30 seconds
◉P6 securing. Answer: 1. Return the throttle to the "IDLE" position.
2. Close the fuel valve by pushing it to the left to the "OFF" position.
3. Shut down the engine by turning the ignition switch counter
clockwise to the "OFF" position
◉P6 Fittings. Answer: 15' 3" dia camlock rigid suction hose with
strainer, 20' 3" dia camlock fiber reinforced flexible hose
250GPM@12' lift @3900RPM, Set the throttle about 1/3 open.,
◉P6 speeds. Answer: Idle 1400 full throttle 3900
◉Pressure gauge and transducer calibration interval. Answer: 24
months