Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Driver operator mobile water Actual Exam Study Questions with Verified Results

Beoordeling
-
Verkocht
-
Pagina's
23
Cijfer
A+
Geüpload op
06-04-2026
Geschreven in
2025/2026

Driver operator mobile water Actual Exam Study Questions with Verified Results 1. Identify FIVE requirements for a MWS apparatus that can be found in NFPA 1901 – ANSWER a. An MWS apparatus equipped with a fire pump must have a tank to pump line at least two inches in diameter and be capable of supplying the pump with 500 GPM until at least 80% of the tank is emptied. b. An MWS apparatus must be equipped with at least one external fill connection connected into the tank that allows the tank to be filled at a minimum rate of 1000 GPM. c. The external fill connection should be equipped with a valve, strainer, and a 30 degree elbow. d.Valves that are three inches or larger must be of the slow closing design. e. An MWS apparatus must have at least three large tank discharges capable of discharging 90% of the tank volume at an average of 1000 GPM. 2. Pressure Control Test - ANSWER a. Engage the pump and set it to the pump capacity. b. Set the pressure control device. c. Close the discharge valves. d. Note the pump discharge 3. The three parts of the pressure control test require you to close the flowing valves one at a time: - ANSWER In no less than 3 seconds and no more than 10 seconds 4. The gauge and flow meter readings with actual pitot tube readings. The two readings should differ by no more than: - ANSWER 10% 5. The tank to pump flow rate test measures whether the piping between an apparatus water tank and fire pump meets the minimum flow standards of: - ANSWER NFPA 1901 6. Rope or test stand - ANSWER Secures test nozzles 7. Pitot tube - ANSWER Measures the velocity pressure of a stream of water 8. Tachometer - ANSWER Checks engine speed 9. Solid stream nozzles - ANSWER Needed to match the volumes pumped for different tests 10.Compound gauge - ANSWER Checks the pump intake pressure 11.Flow Meter - ANSWER Reads the flow of water directly in GPM 12.Identify the TWO most important reasons for maintaining good MWS apparatus records. - ANSWER Keeps everyone on the team informed about equipment conditions. 13.When Checking the left front or right front side of the fire apparatus, don't forget to inspect the: - ANSWER saddle tanks 14.Daily inspection - ANSWER Ensure auxiliary fuel tank is full Operate pump primer Inspect auxiliary winterization system. 15.Weekly Inspection - ANSWER Clean intake strainers 16.Pre-service pump certification test are conducted by: - ANSWER An independent testing agency 17.When using a static body of water as your water source during fire apparatus service testing, the water surface must not be more than___ feet above the centerline of the pump intake and the water must be at least _____ feet deep. - ANSWER 10 Feet above 4 Feet deep 18.If the engine speed check proves the MWS apparatus is running at a different speed than what which it was originally rated, you need to? - ANSWER Stop the testing until the problem is corrected. 19.A year has passed and its time conduct the annual vacuum test on your departments MWS apparatus. You're following the procedures for conducting the vacuum test and you've already checked for and removed foreign matter from the hard suction hose. The next step to perform while conducting the vacuum test is to: - ANSWER Connect 20 Feet of the hard suction hose to the pump intake connection. 20.When conducting a priming device test and using a pump of less than 1500 GPM, the priming device should be able to create the necessary vacuum in ____ seconds to lift water 10 feet through 20 feet of hard suction hose. - ANSWER 30 seconds 21.Place the steps for conducting a pumping test in the correct order. - ANSWER 1. Gradually speed up the pump until the net pump discharge pressure is 150 PSI 2. Use a pitot tube or a flow meter to check the flow of water at the nozzle. 3.Record six different readings at 5-minute intervals for a total of 20 minutes. 4. Set the net pump discharge pressure to 200 PSI. 5. Set the net pump discharge pressure to 250 PSI. 22.An MWS apparatus may have steering system problems if the steering wheel can be rotated (without moving front tires) more than: - ANSWER 10 degrees

Meer zien Lees minder
Instelling
Driver Operator Mobile Water
Vak
Driver operator mobile water

Voorbeeld van de inhoud

Driver operator mobile water Actual Exam
Study Questions with Verified Results

1. Identify FIVE requirements for a MWS apparatus that can be found in
NFPA 1901 –
ANSWER a. An MWS apparatus equipped with a fire pump must have a tank
to pump line at least two inches in diameter and be capable of supplying the
pump with 500 GPM until at least 80% of the tank is emptied.


b. An MWS apparatus must be equipped with at least one external fill
connection connected into the tank that allows the tank to be filled at a
minimum rate of 1000 GPM.


c. The external fill connection should be equipped with a valve, strainer, and a
30 degree elbow.


d.Valves that are three inches or larger must be of the slow closing design.


e. An MWS apparatus must have at least three large tank discharges capable of
discharging 90% of the tank volume at an average of 1000 GPM.


2. Pressure Control Test - ANSWER a. Engage the pump and set it to the
pump capacity.


b. Set the pressure control device.


c. Close the discharge valves.

,d. Note the pump discharge


3. The three parts of the pressure control test require you to close the flowing
valves one at a time: - ANSWER In no less than 3 seconds and no more
than 10 seconds


4. The gauge and flow meter readings with actual pitot tube readings. The two
readings should differ by no more than: - ANSWER 10%


5. The tank to pump flow rate test measures whether the piping between an
apparatus water tank and fire pump meets the minimum flow standards of: -
ANSWER NFPA 1901


6. Rope or test stand - ANSWER Secures test nozzles


7. Pitot tube - ANSWER Measures the velocity pressure of a stream of water


8. Tachometer - ANSWER Checks engine speed


9. Solid stream nozzles - ANSWER Needed to match the volumes pumped for
different tests


10.Compound gauge - ANSWER Checks the pump intake pressure


11.Flow Meter - ANSWER Reads the flow of water directly in GPM

, 12.Identify the TWO most important reasons for maintaining good MWS
apparatus records. - ANSWER Keeps everyone on the team informed about
equipment conditions.


13.When Checking the left front or right front side of the fire apparatus, don't
forget to inspect the: - ANSWER saddle tanks


14.Daily inspection - ANSWER Ensure auxiliary fuel tank is full


Operate pump primer


Inspect auxiliary winterization system.


15.Weekly Inspection - ANSWER Clean intake strainers


16.Pre-service pump certification test are conducted by: - ANSWER An
independent testing agency


17.When using a static body of water as your water source during fire apparatus
service testing, the water surface must not be more than___ feet above the
centerline of the pump intake and the water must be at least _____ feet deep.
- ANSWER 10 Feet above


4 Feet deep


18.If the engine speed check proves the MWS apparatus is running at a
different speed than what which it was originally rated, you need to? -
ANSWER Stop the testing until the problem is corrected.

Geschreven voor

Instelling
Driver operator mobile water
Vak
Driver operator mobile water

Documentinformatie

Geüpload op
6 april 2026
Aantal pagina's
23
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
DrSammuel

Maak kennis met de verkoper

Seller avatar
DrSammuel TeachmeTutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
4
Lid sinds
4 maanden
Aantal volgers
0
Documenten
660
Laatst verkocht
2 weken geleden
Turning Preparation into Achievement.

Welcome to my study resource hub! This account provides high-quality exam papers with clear and detailed elaborations designed to help students fully understand each topic and pass with confidence.

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen