APPLICATION OF US ARMY ESQD PRINCIPLES |
FREQUENTLY TESTED QUESTIONS WITH
CORRECT ANSWERS | BRAND NEW!
Any location containing ammunition and explosives that could
create a blast if an explosion occurs in a/an - ✔✔✔ Correct Answer >
barricaded administration building
exposed site
potential exposed site
>potential explosion site<
What is the maximum amount of NEW you can store in this
potential explosion site (PES)?
PES: ECM, side-facing HD 1.1 NEW
D=1,426
ES: Public traffic route - ✔✔✔ Correct Answer > 70,000 lbs
100,000 lbs
>150,000 lbs<
200,000 lbs
, Page 2 of 14
What is the minimum separation distance between this potential
explosion site (PES) and exposed site (ES)?
PES: Service ECM, rear-facing HD 1.1 NEW=30,000 lbs
ES: Operating building - ✔✔✔ Correct Answer > 186 ft
280 ft
373 ft
>559 ft<
What is the maximum amount of net explosives weight (NEW)
you can store in this potential explosion site (PES)?
PES: operating building HD 1.1
D=373 ft (barricade)
ES: operating building - ✔✔✔ Correct Answer > 30,000 lbs
50,000 lbs
>70,000 lbs<
100,000 lbs
What is the minimum separation distance between this potential
explosion site (PES) and exposed site (ES)?