COMPLETE 600 QUESTIONS AND CORRECT
DETAILED ANSWERS (VERIFIED ANSWERS)
ALREADY GRADED A+
____________ is pressure gained when the nozzle is below the pump. - CORRECT ANSWER:
Elevation gain
______________ expansion describes the ratio of finished foam solution after the concentrate is
mixed with water, agitated, and aspirated through a foam-making appliance. - CORRECT
ANSWER: Foam
______________ is pressure lost when the nozzle is above the pump. - CORRECT ANSWER:
Elevation loss
_______________ evolutions are standard methods of working with fire hose to accomplish
different objectives in a variety of situations. - CORRECT ANSWER: Fire hose
_______________ has a significant effect on the weight of water. - CORRECT ANSWER:
Temperature
________________ foam is particularly useful for protecting buildings in rural areas during
forest and brush fires when the water supply is limited. - CORRECT ANSWER: Class A
________________ is the forward pressure measured at a discharge opening while water is
moving. - CORRECT ANSWER: Flow pressure
________________ is the process of of pouring foam concentrate directly into the fire apparatus
water tank, thereby mixing a large amount of foam at one time. - CORRECT ANSWER: Batch
mixing
,________________ refers to the pressure required at the nozzle to deliver the fire stream and
flow rate for which the nozzle was designed. - CORRECT ANSWER: Nozzle pressure
_________________ pressure in a system is identified by water that is not moving. - CORRECT
ANSWER: Static
__________________ foams are used for the exinguishment of Class B fires involving
hydrocarbons. - CORRECT ANSWER: Protein
__________________ is the term used to describe pressure in a water system during a period of
normal consumption. - CORRECT ANSWER: Normal operating pressure
__________________ nozzles produce fine droplets of water that absorb heat quickly. -
CORRECT ANSWER: Fog stream
___________________ are a proactive means that critical functions are assigned to team
members prior to arrival. - CORRECT ANSWER: Assigned riding positions
___________________ inspections include all on-board systems and all carried equipment. -
CORRECT ANSWER: Routine
___________________ is a key consideration for the driver/operator that is critical for building a
successful team, instilling confidence in crew members, and supporting positive response
outcomes. - CORRECT ANSWER:
___________________ is defined as the cessation of proper functioning or performance. -
CORRECT ANSWER: Failure
___________________ systems are the most common of system in use today and are designed
for use with Class A foam and with many Class B foam concentrates, depending on the viscosity
of the concentrate. - CORRECT ANSWER: Injection
,______________________ is the term used to describe a pressure surge or wave caused by the
kinetic energy of a fluid in motion when it is forced to stop or change direction suddenly. -
CORRECT ANSWER: Water hammer
______________________ is the term used to describe the amount of pressure that remains in
the system when water is flowing. - CORRECT ANSWER: Residual Pressure
_________________________ along with a variety of state and provincial health and safety
agencies, develops and enforces government regulations on workplace safety, and in some cases,
responder safety. - CORRECT ANSWER: Occupational Safety and Health Administration
(OSHA)
___________________________ are the best sources for retrieving the answers to specific
equipment operational questions. - CORRECT ANSWER: Operating Manuals
( # of stories -1) X 5 - CORRECT ANSWER: Formula for EP
= 0.0505 X GPM X √NP - CORRECT ANSWER: Fog Nozzle Reaction
1.57 X d² X NP - CORRECT ANSWER: Smooth Bore Nozzle Reaction
1000 gallons (4000 L) - CORRECT ANSWER: A mobile water supply apparatus is equipped
with one or more water tanks that meet the requirements of NFPA 1901 and have a minimum
certified capacity of:
1000 gallons (4000 L) - CORRECT ANSWER: In order for a fire apparatus to be classified as a
mobile water supply apparatus, it must have a water tank that holds a minimum of:
, 115 Ft (35 M) - CORRECT ANSWER: According to NFPA 1901, for a fire apparatus to meet the
classification of aerial, what is the minimum number of feet in length that the total complement
of ground ladders must meet?
115 ft (35 m) - CORRECT ANSWER: To be considered an aerial fire apparatus as defined by
NFPA 1901, the apparatus must include at a minimum, a _____________ total complement of
ground ladders that are supplied and installed by the manufacturer.
15 ft (4.5 m); 20 ft (6m) - CORRECT ANSWER: If a mobile water supply apparatus is equipped
with a fire pump, it must carry a minimum of ___________ of soft suction hose _____________
of hard suction hose with a strainer.
1911 - CORRECT ANSWER: Performance testing is typically performed by a qualified EVT
level 2 technician, as defined by NFPA:
2 - CORRECT ANSWER: In order for a fire apparatus to be classified as a "quint". It must carry
a minimum of ___________ combination spray nozzles capable of flowing 95 GPM (360 L/Min)
200 gallons (750 L - CORRECT ANSWER: According to NFPA 1901, in order for a fire
apparatus to be classified as an initial attack fire apparatus, it must have a water tank capable of
carrying a minimum of:
200:1 to 1000:1 - CORRECT ANSWER: High-expansion foam has a foam expansion ratio in the
range of:
250 (1000 L/Min) - CORRECT ANSWER: According to NFPA 1901, in order for a fire
apparatus to be classified as an initial attack fire apparatus, it must have a pump rated a minimum
of ___________ GPM.
29.7 X d² X √NP - CORRECT ANSWER: Formula for GPM