COMPLETE 60 QUESTIONS AND CORRECT
DETAILED ANSWERS (VERIFIED ANSWERS)
ALREADY GRADED A+
Aerial ladder devices with water delivery systems may be equipped with remote controls that
allow the driver/operator to manipulate the: - CORRECT ANSWER: fire stream pattern.
After the apparatus is stabilized laterally on uneven terrain, it is preferable to operate the aerial
device over the: - CORRECT ANSWER: uphill side of the apparatus.
Driver/operators should examine electrical cords daily: - CORRECT ANSWER: for damage to
insulation and connections.
During the initial setup, it is the driver/operator's responsibility to: - CORRECT ANSWER:
consider the potential water supply demand.
Generally SOPs involving apparatus placement at a fire scene apply to: - CORRECT ANSWER:
aerial apparatus assigned to the initial response.
How might a Fire Fighter I exhibit situational awareness in action on the fireground? -
CORRECT ANSWER: Notifying the IC that he or she noticed fire spreading to another area of
the building
If a litter does not fit between rails of the aerial ladder, firefighters should: - CORRECT
ANSWER: place the litter on top of handrails perpendicular to the ladder.
If an apparatus is to be positioned in a dead-end access, it should be backed into position if
possible because it will: - CORRECT ANSWER: make an escape faster if it becomes necessary.
, In addition to a control pedestal on the turntable, NFPA® 1901 also requires a control station: -
CORRECT ANSWER: in the platform.
Manual stabilizers are most likely to be found on: - CORRECT ANSWER: older midship and
tractor-drawn aerials.
Newer operators should avoid full-speed operations until: - CORRECT ANSWER: they are very
familiar with the operation of the aerial device.
NFPA® 1901 requires a protective water fog curtain nozzle to be provided on the bottom of an
elevated platform that can be operated to: - CORRECT ANSWER: provide an additional barrier
when the platform is exposed to high levels of heat.
Raising the telescoping aerial device means which of the following? - CORRECT ANSWER:
Elevating the entire assembly from its stored position to a desired angle and useful position
Standard fire hydrants have at least one large steamer connection and: - CORRECT ANSWER:
two hose outlet nozzles for 2½-inch (65 mm) couplings.
Techniques for jackknifing tillered aerial apparatus are more important on older models of
apparatus than on modern tillered aerial apparatus because: - CORRECT ANSWER: most
modern apparatus are equipped with stabilization systems capable of stabilizing the apparatus,
whether jackknifed or not.
The driver/operator should not engage the PTO until the aerial apparatus has been: - CORRECT
ANSWER: properly positioned in accordance with the conditions on the scene.
The function of the hydraulic system is to provide power for operating the various hydraulic
components needed to: - CORRECT ANSWER: stabilize the apparatus and operate the aerial
device.