TN Burglar Alarm Systems Qualifying Agent exam ACTUAL
EXAM COMPLETE QUESTIONS AND CORRECT ANSWERS
LATEST UPDATE THIS YEAR
Summarized Exam Coverage
The TN Burglar Alarm Systems Qualifying Agent exam focuses on alarm system components, installation
practices, wiring methods, and system design. It also evaluates knowledge of control panels, sensors,
communication systems, and monitoring operations.
Key emphasis is placed on Tennessee regulations, licensing requirements, false alarm prevention, and
compliance with local ordinances. Candidates must understand testing, troubleshooting, and
maintenance procedures to ensure system reliability.
The exam also covers electrical fundamentals, safety standards, proper equipment installation, and
system configuration. Additionally, candidates are expected to demonstrate knowledge of central
station monitoring, alarm signal transmission, and response protocols.
1.
A technician installs a motion detector near an HVAC vent and notices frequent false alarms triggered by
air movement; what is the most appropriate corrective action?
, Page 2 of 112
A. Increase sensor sensitivity
B. Relocate the motion detector away from airflow sources
C. Disable the HVAC system permanently
D. Replace the control panel
Answer: B
Rationale: Air movement can trigger motion sensors; relocating avoids environmental interference.
2.
A burglar alarm system loses communication during power outages despite having backup batteries;
what is the most likely issue?
A. Battery capacity is insufficient or failing
B. Sensors are defective
C. Wiring is oversized
D. Keypad malfunction only
Answer: A
Rationale: Backup batteries must support communication modules during outages.
, Page 3 of 112
3.
Which type of sensor is most appropriate for detecting glass breakage in a storefront environment?
A. Magnetic contact switch
B. Acoustic glass break detector
C. Motion detector only
D. Smoke detector
Answer: B
Rationale: Acoustic detectors are specifically designed to detect glass break frequencies.
4.
A system continuously reports false alarms from a door contact sensor; what is the most likely cause?
A. Incorrect wiring or misalignment of the magnetic contact
B. Excessive battery voltage
C. Control panel overheating
D. Improper keypad programming
Answer: A
Rationale: Misalignment or wiring issues cause inconsistent contact signals.
, Page 4 of 112
5.
Which component is responsible for managing all inputs and outputs in a burglar alarm system?
A. Keypad
B. Control panel
C. Motion sensor
D. Siren
Answer: B
Rationale: The control panel processes signals from all system devices.
6.
A technician installs a wireless alarm system but experiences frequent signal loss; what is the most
probable cause?
A. Improper grounding
B. RF interference or range limitations
C. Incorrect voltage supply
D. Faulty keypad display