Certified Chimney Sweep Exam ||Verified Exam!!!||
Most Recent Exam Actual Complete Real Exam
Questions And Correct Answers (Verified Answers)
Already Graded A+ | Guaranteed Success!! | Newest
Exam!!!
the pipe that connects a fuel burning appliance to a
chimney or vent - Answer-Connector
the rapid oxidation of fuel accompanied by the production
of heat and light - Answer-Combustion
Primary reason creosote must be removed from chimney
systems - Answer-Chimney Fire
What must a chimney sweep recommend after a chimney
fire has occurred? - Answer-Level 2 inspection
The Association of Pellet Fuel Manufacturers, recommend
that pellet fuel should have how many BTU's per pound? -
Answer-8200 BTU's per pound
,2|Page
Heat that cannot be felt or measured but is potential heat
bound up in the form of a material - Answer-Latent
natural product of burning wood - Answer-Creosote
Creosote is a ______ - Answer-Carcinogen
measure of heat required to raise one pound of water one
degree F - Answer-BTU
An enclosure for a chimney that is used to separate the
chimney from the living area or to hide an exterior chimney
from view is called a - Answer-Chase
3 elements needed for fire - Answer-Heat, Air, Fuel
3 stages of combustion - Answer-Drying, Pyrolysis,
Charcoal
3 things necessary for complete combustion - Answer-
Temperature, Turbulence, Time
,3|Page
amount of unburned hydrocarbons in the flue gas -
Answer-Smoke Density
length of time smoke remains in the venting system -
Answer-Residence Time
raise the effeciency of the wood stove and lower
particulate emissions - Answer-Catalytic combustors
To acheive light off the catalytic unit should be preheated
to ________ for about ________ - Answer-500 degrees,
10 minutes
a vavle, usually a moveable or retractable plate for
controlling the flow of air or smoke. - Answer-Damper
One or more passageways, vertical or nearly so, for
conveying flue gases from the appliance to the outside
atmosphere - Answer-Chimney
Portion of an appliance that is designed for attachment of
a chimney, vent connector or a draft hood is a - Answer-
Flue Collar
, 4|Page
Sheet metal or other materials used in waterproofing roof
valleys, hips or the angle between a chimney and a roof -
Answer-Flashing
A device designed for use with the chimneys that
penetrate the roof at a location other than the roof peak
and will often shed water away from the chimney -
Answer-Cricket
Units of masonry projecting from or stepping outward and
upward from the face of a wall or chimney in courses to
form a support or ledge for a beam or rafter or used to
change the shape or direction of a chimney are called -
Answer-Corbel
colorless, odorless, non-combustible gas produced during
complete combustion of fuel - Answer-Carbon Dioxide
(CO2)
Colorless, odorless, toxic gas produced from incomplete
combustion of fuel - Answer-Carbon Monoxide (CO)