Test Study Guide Questions and Correct
Answers| Latest Update
How many apprentices can a journeyman directly supervise?
2
When performing any service work on a customers heating system the licensee
must notify the homeowner of?
Efficiency and code violations
Can a licensed journeyman perform a cleaning on wood/oil combination unit
without direct supervision?
No
When installing a furnace, direct wired water heater or boiler what must be done
prior to placing it in service?
Everything complies with NFPA 31 code
,When installing a new oil burner the _______ must be brought into compliance
with the rules of the board before ______?
Wiring Start up
When an emergency situation arises that does not allow adequate time to get the
chimney lined/repaired before installing the new heating appliance what can be
done?
90 day waiver
Who is responsible for ensuring repairs or the chimney is lined within the 90 days?
Installer\Licensee
When is a heat loss required?
For new install
Prior to a boiler replacement a________ or a ________ Must be conducted before
replacement of an existing system.
Heat loss/ heat load
, The low-water cut off must be located where?
6 inches above boiler crown sheet but in no case below
An oil supply or return line under cement subfloor or earth must be ________ And
without ________?
Sleeved Fittings (continuous)
Coated copper tubing must have _______ Installed at the tank when ________?
OSV Underground
Whenever an outlet of an oil supply tank is located more than ______ above the
burner a _____ or _____ valve is required.
4ft OSV or PRV
Unprotected lines that are buried or grouted must be?
removed from service