1. Which of the following should the inspector be wearing while evaluating
electrical panels?
A. all of these
B. safety glasses
C. non-synthetic clothing
D. none of these
E. electrician's gloves - Correct Answer: A. all of these
2. Which of the following should be reported as a problem with an electrical
panel?
A. unlinked double-pole breakers
B. pigtails (two wires joined to a common breaker)
C. GFCI breakers
D. splices in the panel - Correct Answer: A. unlinked double-pole
breakers
3. A bonding connection ______________________ connect the grounding
bus to the electrical enclosure.
A. should
, B. should not - Correct Answer: A. should
4. Fused main disconnects are usually a maximum of _____.
A. 30 amps
B. 60 amps
C. 100 amps
D. 200 amps - Correct Answer: C. 100 amps
5. Screw-in fuses are more properly called _________.
A. Westinghouse fuses
B. Tessler-type fuses
C. Edison base fuses - Correct Answer: C. Edison base fuses
6. Upgrading to ___ fuses stops over-fusing.
A. A
B. S
C. P
D. F - Correct Answer: B. S
7. Which of the following statements is true about 240-volt breakers?
A. 240-volt breakers draw power from one bus bar.
B. 240-volt breakers are always 15- or 30- amps.
C. 240-volt breakers are connected to two separate bus bars in the
panel.
D. 240-volt breakers should always be located at the very top of the
panel. - Correct Answer: C. 240-volt breakers are connected to
two separate bus bars in the panel.
,8. GFCI breakers have _____ conductors.
A. one
B. two
C. zero
D. three - Correct Answer: B. two
9. The inspector will find overheating _____________ breakers.
A. with any type of defective
B. only with Sylvannia
C. only with Zinsco and FPE - Correct Answer: A. with any type of
defective
10.AFCI breakers made by ________ were subject to a recall notice.
A. Federal Pacific
B. Cutler-Hammer
C. Challenger
D. Square D - Correct Answer: D. Square D
11.Zinsco electrical panels are sometimes branded as ________.
A. Challenger
B. Sylvania
C. Federal Pacific - Correct Answer: B. Sylvania
12.Electric panel buses colored red, blue and black are indicative of a
_____________.
A. 120-volt only supply
B. 3-phase supply
C. 4-phase supply
D. 120/240-volt panels - Correct Answer: B. 3-phase supply
, 13.Zinsco electrical panels are problematic due to __________.
A. difficulty obtaining replacement breakers
B. loose breakers
C. poor connections to the bus
D. not enough amperage for modern needs - Correct Answer: C.
poor connections to the bus
14.Fused neutral circuits were common in the _________.
A. 1900s
B. 1890s
C. 1920s
D. 1910s - Correct Answer: C. 1920s
15.What color will plastic conduit be if it is for electrical use?
A. red-
B. gray
C. white - Correct Answer:
16.The inspector should not report all _______________ electrical splices as
improper.
A. dead front
B. neither
C. in-panel - Correct Answer: C. in-panel
17.Which of the following would the inspector require a specialist?
A. single-strand aluminum wiring
B. aluminum wiring