Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

AWWA practice test ACTUAL EXAM LATEST UPDATE THIS YEAR QUESTIONS AN DETAILED ANSWERS_compressed

Beoordeling
-
Verkocht
-
Pagina's
49
Cijfer
A+
Geüpload op
09-04-2026
Geschreven in
2025/2026

Tap on AVAILABLE IN BUNDLE / PACKAGE DEAL to unlock free bonus exams — save more while getting everything you need! You’ll be glad you did! The AWWA Practice Test ACTUAL EXAM – ALL QUESTIONS AND DETAILED ANSWERS LATEST UPDATE THIS YEAR – JUST RELEASED delivers a fully updated and comprehensive study resource designed to help water works professionals confidently prepare for American Water Works Association (AWWA) certification and state licensing exams. This in-depth exam guide covers all essential topics typically assessed in water operator certification, including water treatment processes, distribution system operations, water quality and testing, equipment maintenance, safety protocols (OSHA), and federal and state drinking water regulations (SDWA). The complete practice set mirrors current industry testing formats and includes scenario-based, multiple-choice, and technical calculation questions that strengthen both theoretical knowledge and practical operational skills. Each question is paired with a verified, detailed answer to reinforce learning, clarify complex hydraulic and chemical concepts, and enhance overall exam readines

Meer zien Lees minder
Instelling
AWWA
Vak
AWWA

Voorbeeld van de inhoud

A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT SHALL
INCLUDE ALL OF THE FOLLOWING INFORMATION EXCEPT THE:
A) ADDRESS OF THE INSTALLATIONB) SERIAL NUMBER OF THE ASSEMBLY
C) TEST RESULTS OF CHECK VALVE NUMBER ONE (1)
D) TEST RESULTS OF CHECK VALVE NUMBER TWO (2)
E) DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING


E) DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING


THE BY-PASS LINE OF AN APPROVED BACKFLOW PREVENTION ASSEMBLY MUST CONTAIN AN
APPROVED ASSEMBLY OF EQUAL:
A) CORROSION RESISTANCE
B) FLOW CAPACITY
C) PROTECTION
D) SIZE
E) TEMPERATURE RATING


C) PROTECTION

,AN ATMOSPHERIC TYPE VACUUM BREAKER SHALL NOT BE SUBJECTED TO WATER PRESSURE FOR
PERIODS THAN ______ HOURS.
A) SIX (6)
B) EIGHT (8)
C) TWELVE (12)
D) TWENTY-FOUR (24)
E) NONE OF THE ABOVE


C) TWELVE (12)


IT IS POSSIBLE FOR A PERFECT VACUUM AT SEA LEVEL TO RAISE WATER IN A PIPE APPROXIMATELY
_________ FEET.
A) TWENTY-FIVE (25)
B) THIRTY (30)
C) THIRTY-TWO (32)
D) THIRTY-FOUR (34)
E) THIRTY-SIX (36)


D) THIRTY-FOUR (34)

,WHAT IS THE MOST DESIRABLE PLACE TO INSTALL A BACKFLOW PREVENTION DEVICE AND/OR
ASSEMBLY?
A) IN A REINFORCED CONCRETE PIT
B) IN AN ACCESSIBLE LOCATION ABOVE GROUND
C) UNDERGROUND, WITH A MINIMUM OF TWELVE (12) INCHES OF COVER
D) AT OR ABOVE CEILING HEIGHT, TO PROTECT IT FROM VANDALISM
E) BEHIND THE BOILER OR EQUIPMENT SERVED, SO IT CAN BE WORKED ON WHEN THE EQUIPMENT IS
REMOVED


B) IN AN ACCESSIBLE LOCATION ABOVE GROUND


WHICH OF THE FOLLOWING CONDITIONS COULD RESULT IN WATER CONTAMINATION THROUGH A
CROSS-CONNECTION?
A) A VACUUM CREATED BY THE IMPROPER USE OF WATER HAMMER ARRESTERS
B) THE USE OF SELF CLOSING LAVATORY FAUCETS
C) TURNING OFF SERVICE TO A MULTI-STORY BUILDING AND ALLOWING THE WATER SUPPLY TO DRAIN
D) A VACUUM CREATED BY THE USE OF QUICK CLOSING VALVES ON THE LOWER FLOORS OF A BUILDING
EXCEEDING TEN (10) FLOORS IN HEIGHT
E) THE INSTALLATION OF WATER CONSERVING FIXTURES, INTO A BUILDING DESIGNED PRIOR TO THEIR
REQUIRED US


C) TURNING OFF SERVICE TO A MULTI-STORY BUILDING AND ALLOWING THE WATER SUPPLY TO DRAIN

, WHAT IS ANOTHER TERM THAT DESCRIBES WATER QUALITY AS A HEALTH HAZARD RESULTING FROM
BACKFLOW?
A) ISOLATION
B) CONTAMINATION
C) CROSS-CONNECTION
D) POLLUTION
E) CONTAINED


B) CONTAMINATION


THE VENTURI EFFECT STATES THAT WHEN THE WATER VELOCITY WITHIN THE PIPE INCREASES, THE
PRESSURE:\
A) WILL INCREASE PROPORTIONATELY
B) WILL REMAIN CONSTANT
C) COMPRESSES EXCESS VOLUMES OF WATER
D) DECREASES
E) CREATES BACKPRESSURE


D) DECREASES

Geschreven voor

Instelling
AWWA
Vak
AWWA

Documentinformatie

Geüpload op
9 april 2026
Aantal pagina's
49
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$28.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
surepass Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
6621
Lid sinds
3 jaar
Aantal volgers
20
Documenten
1462
Laatst verkocht
13 uur geleden

5.0

437 beoordelingen

5
428
4
3
3
2
2
2
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen