Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

MRI ARMRIT Exam Questions Version 3 /MRI ARMRIT prep Exam Questions and Answers Practice Questions with Solutions Newest | Already Graded A+

Beoordeling
-
Verkocht
-
Pagina's
99
Cijfer
A+
Geüpload op
11-04-2026
Geschreven in
2025/2026

MRI ARMRIT Exam Questions Version 3 /MRI ARMRIT prep Exam Questions and Answers Practice Questions with Solutions Newest | Already Graded A+ The optimal imaging plane for visualization of a TFCC tear is: A. Axial B. Coronal C. Transverse D. Sagittal E. None of the above Coronal Diseases, such as malaria, in which microorganisms are transferred via an insect, come under the classification of __________ infections. A. Indirect contact B. Vector borne 2 MRI ARMRIT Exam C. Nosocomial D. Common vehicle Vector borne What is the percentage of patients reported to have allergic reactions to gadolinium contrast agents? A. 1% B. 5% C. 10% D. 15% E. 20% 1% Which of the following parameter adjustments will LENGTHEN scan time in an MR pulse sequence? I. Decrease TR II. Increase TR III. Increase ETL IV. Decrease ETL V. Decrease NEX VI. Increase NEX VII. Enable Half-fourier VIII. Increase parallel imaging factor IX. Decrease parallel imaging factor X. Enable anti-aliasing II, IV, VI and IX Which of the following parameter adjustments help to improve SNR in an MR image? I. Increase TR II.Reduce Phase Matrix III. Reduce Pixel Size IV. Increase FOV V. Reduce rBW VI. Increase rBW VII. Increase NSA VIII. Decrease NSA IX. Increase ETL X. Decrease ETL I, II, IV, V, VII and X 3 MRI ARMRIT Exam In a fast spin echo sequence with a 25 cm FOV, 224 x 320 matrix, TR 2500, 100 TE, 3mm slice thickness, 12 ETL and 4 NEX, the scan time would be: A. 2 minutes 6 seconds B. 3 minutes 7 seconds C. 3 minutes 11 seconds D. 4 minutes 27 seconds E. 4 minutes 44 seconds 3 minutes 7 seconds The phase encoding step is performed: A. During frequency encoding B. In place of frequency encoding C. Prior to frequency encoding D. Following frequency encoding Prior to frequency encoding Permanent magnets with a vertical magnetic field use surface coils that are: A. Phased array B. Linear C. Quadrature D. Solenoids Solenoids Gradient echo sequences can yield either T1 or T2* characteristics, with influences caused by all of the following EXCEPT: A. Chemical shift B. Inhomogeneity C. Susceptibility D. Inversion time Inversion time In what orientation would a tear of the collateral ligaments of the knee be best visualized? A. Sagittal B. Axial C. Transverse D. Coronal E. None of the above Coronal RF energy used in MRI is classified as: A. Low energy, nonionizing radiation

Meer zien Lees minder
Instelling
MRI ARMRIT
Vak
MRI ARMRIT

Voorbeeld van de inhoud

1
MRI ARMRIT Exam
MRI ARMRIT Exam Questions Version 3
/MRI ARMRIT prep Exam Questions and
Answers Practice Questions with
Solutions Newest | Already Graded A+




The optimal imaging plane for visualization of a TFCC tear is:
A. Axial
B. Coronal
C. Transverse
D. Sagittal
E. None of the above
Coronal
Diseases, such as malaria, in which microorganisms are transferred via an insect, come under
the classification of __________ infections.
A. Indirect contact
B. Vector borne

, 2
MRI ARMRIT Exam
C. Nosocomial
D. Common vehicle
Vector borne
What is the percentage of patients reported to have allergic reactions to gadolinium contrast
agents?
A. 1%
B. 5%
C. 10%
D. 15%
E. 20%
1%
Which of the following parameter adjustments will LENGTHEN scan time in an MR pulse
sequence?
I. Decrease TR
II. Increase TR
III. Increase ETL
IV. Decrease ETL
V. Decrease NEX
VI. Increase NEX
VII. Enable Half-fourier
VIII. Increase parallel imaging factor
IX. Decrease parallel imaging factor
X. Enable anti-aliasing
II, IV, VI and IX
Which of the following parameter adjustments help to improve SNR in an MR image?
I. Increase TR
II.Reduce Phase Matrix
III. Reduce Pixel Size
IV. Increase FOV
V. Reduce rBW
VI. Increase rBW
VII. Increase NSA
VIII. Decrease NSA
IX. Increase ETL
X. Decrease ETL
I, II, IV, V, VII and X

, 3
MRI ARMRIT Exam
In a fast spin echo sequence with a 25 cm FOV, 224 x 320 matrix, TR 2500, 100 TE, 3mm slice
thickness, 12 ETL and 4 NEX, the scan time would be:
A. 2 minutes 6 seconds
B. 3 minutes 7 seconds
C. 3 minutes 11 seconds
D. 4 minutes 27 seconds
E. 4 minutes 44 seconds
3 minutes 7 seconds
The phase encoding step is performed:
A. During frequency encoding
B. In place of frequency encoding
C. Prior to frequency encoding
D. Following frequency encoding
Prior to frequency encoding
Permanent magnets with a vertical magnetic field use surface coils that are:
A. Phased array
B. Linear
C. Quadrature
D. Solenoids
Solenoids
Gradient echo sequences can yield either T1 or T2* characteristics, with influences caused by
all of the following EXCEPT:
A. Chemical shift
B. Inhomogeneity
C. Susceptibility
D. Inversion time
Inversion time
In what orientation would a tear of the collateral ligaments of the knee be best visualized?
A. Sagittal
B. Axial
C. Transverse
D. Coronal
E. None of the above
Coronal
RF energy used in MRI is classified as:
A. Low energy, nonionizing radiation

, 4
MRI ARMRIT Exam
B. Low energy, ionizing radiation
C. High energy, nonionizing radiation
D. High energy, ionizing radiation
Low energy, nonionizing radiation
On T1 weighted images of the spine, the CSF (cerebrospinal fluid) appears:
A. Isointense to the spinal cord
B. Hypointense to the spinal cord
C. Hyperintense to the spinal cord
D. None of the above
Hypointense to the spinal cord
Single order gradient moment nulling does not compensate for:
A. Constant velocity flow
B. Accelerated flow
C. Reverse flow
D. B and C
B and C
The gradient rise time is defined as the:
A. Time it takes longitudinal magnetization to regrow
B. Time between TI and initial RF pulse
C. Speed rate of ascent or descent of a gradient from zero to its maximum amplitude
D. Time it takes for the gradient to reach its full amplitude
Time it takes for the gradient to reach its full amplitude
In an MRA sequence, the removal of signal from vessels is accomplished by:
A. Spectral presaturation
B. Spatial presaturation
C. Gradient moment nulling
D. B and C
E. None of the above
Spatial presaturation
CSF suppression is performed with which type of technique?
A. FLAIR
B. STIR
C. SPGR
D. FISP
FLAIR

Geschreven voor

Instelling
MRI ARMRIT
Vak
MRI ARMRIT

Documentinformatie

Geüpload op
11 april 2026
Aantal pagina's
99
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$23.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
JoyceWWales Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
125
Lid sinds
2 jaar
Aantal volgers
17
Documenten
2505
Laatst verkocht
4 weken geleden
MitchelleWales

HI, WELCOME TO MY PAGE EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF AN A+ Hi there! I'm JOYCE, I'm, a dedicated medical doctor (MD) with a passion for helping students excel in their exams. With my extensive experience in the medical field, I provide comprehensive support and effective study techniques to ensure academic success. My unique approach combines medical knowledge with practical strategies, making me an invaluable resource for students aiming for top performance. Discover my proven methods and start your journey to academic excellence with me on Stuvia today and I'm here to provide high-quality study materials to help you succeed. With a focus on clarity and usefulness, my notes are designed to make your studying easier and more efficient. If you ever need assistance or have any questions, feel free to reach out.

Lees meer Lees minder
3.9

26 beoordelingen

5
14
4
2
3
6
2
1
1
3

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen