What is the purpose of a pressure maintenance pump? - Answer-Prevent false starts

On a diesel engine controller if the pump is the sole supply to standpipes or sprinkler
systems, the automatic start controller should: - Answer-be wired for manual shutdown.

What is the purpose of a speed governor on a steam turbine controller? - Answer-
Maintain the rated speed for the maximum pump load.

Which of the following components has the purpose of preventing pressures from
reaching levels that are high enough to damage system piping or fittings? - Answer-
INCORRECT: Pressure maintenance pump

relief valve?

More modern pump installations: - Answer-INCORRECT: have newer test headers and
hose valves for testing.

When pumps require only a single gauge, it will be located: - Answer-on the discharge
line.

Indoor fire pump units must be: - Answer-separated from all other areas of the building
by fire rated construction.

When operating against a closed system, or at churn, a pump must not develop more
than: - Answer-140 percent of its rated pressure.

At a minimum, how often should pumps be operated? - Answer-At least weekly

A flow test of the pump assembly is required: - Answer-annually.

Which of the following is the LEAST likely reason for installation of an automatic
sprinkler system? - Answer-Aesthetic flexibility

, The water supply must be able to deliver the required volume and pressure of water to
the highest or most remote sprinkler in a structure: - Answer-while maintaining a
minimum residual pressure in the system

The most common piping material is: - Answer-ferrous metal

Which of the following refers to piping that connects the sprinkler system to the main
water supply? - Answer-Water supply main

Which of the following will have a drain, pressure gauge, and waterflow alarm device
attached to it? - Answer-System riser

Where is the main control valve located? - Answer-Between the sources of water supply
and the sprinkler system

Which of the following is NOT a common type of control valve? - Answer-Twin

Which of the following valves is used to control underground sprinkler valves and
consists of a hollow metal post attached to the valve housing? - Answer-post indicator
valve (PIV)

How does a frangible bulb device operate? - Answer-A liquid that expands when heated
breaks the bulb

What is the purpose of a fire department connection (FDC)? - Answer-To boost the
pressure and volume of water in the system

The selection of the operating temperature of a sprinkler is determined by the: - Answer-
maximum air temperature expected at the level of sprinkler under normal conditions

Early suppression fast response (ESFR) sprinklers typically react: - Answer-5 to 10
times faster than traditional sprinklers

Which of the following deflector types is used where it is impractical or unsightly to use
sprinklers in an upright position? - Answer-Pendant

Which of the following specialty sprinklers has a primary function protection of the roof
structure? - Answer-Attic

Which of the following statements about wet-pipe sprinkler systems is MOST accurate?
- Answer-They contain water under pressure in the piping at all times

Which of the following statements about dry-pipe systems is MOST accurate? - Answer-
Air or nitrogen under pressure replaces water in the pipes

Written for

Institution
FTC 106
Course
FTC 106

Document information

Uploaded on
April 11, 2026
Number of pages
10
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

15.99 $
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
victoryguide stuvia
Follow You need to be logged in order to follow users or courses
Sold
27
Member since
1 year
Number of followers
1
Documents
2996
Last sold
1 month ago

3.7

10 reviews

5
5
4
0
3
3
2
1
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions