Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

EPA 608 Type 1 2026/2027 COMPLETE QUESTIONS WITH CORRECT DETAILED ANSWERS || GUARANTEED PASS

Beoordeling
-
Verkocht
-
Pagina's
11
Cijfer
A+
Geüpload op
12-04-2026
Geschreven in
2025/2026

EPA 608 Type 1 2026/2027 COMPLETE QUESTIONS WITH CORRECT DETAILED ANSWERS || GUARANTEED PASS 1. Before opening a self contained recovery machine make sure the - ANSWER inlet valve is open, and tank does not contain excessive air (non condensables) 2. The only way to read refrigerant pressure correctly is at - ANSWER a stable known temperature 3. Air in refrigeration systems will cause - ANSWER higher discharge pressures 4. When purging non-condensables abide by - ANSWER operating instruction supplied by equipment manfactuer 5. All refrigerant recovery equipment should be check for what on a daily basis - ANSWER oil level and leaks 6. A system dependent recovery unit has - ANSWER special charcoal activated plastic "bag" containers 7. System dependent equipment captures refrigerant with the assistance of - ANSWER an applicant compressor, external heat source, or vacuum pump 8. A standard vacuum pump can only be used in combination with a - ANSWER non-pressurized container 9. In order to release trapped refrigerant from the compressor oil - ANSWER heat and tap the compressor several times and/ or use a vacuum pump 10. Because appliances with non-operating compressors can not always achieve desired evacuation rates utilizing system dependent equipment - ANSWER The EPA requires at least one self contained recovery device available at the shop 11. The exception to the EPA required rule of a self contained device available is technicians - ANSWER working on small appliances only 12. System dependent devices may only be used on appliances - ANSWER containing 15 lbs. of refrigerant or less. 13. When installing an access fitting onto a sealed system, - ANSWER the fitting should be leak tested before proceeding with recovery. 14. It is generally recommended that _____ ____ type valves be used on only copper or aluminum tubing material, these fitting tend to leak over time and should not be left on a permanent service fixture. - ANSWER Solder-less piercing 15. After installing a access fitting you the system pressure to be 0 PSIG - ANSWER do not begin recovery process. 16. Operating a defrost heater on a domestic frost free refrigerator will help to - ANSWER vaporize any trapped liquid refrigerant and will speed the recovery process. 17. When recovering refrigerant from a system that experienced a compressor burn-out, - ANSWER watch for signs of contamination in the oil. 18. Small appliances may use such refrigerants as __,___,___ and therefore should not be recovered with current using current recovery equipment. - ANSWER Ammonia, Hydrogen, Water 19. the fitting should be leak tested before proceeding with recovery - ANSWER When installing any type of access fitting onto a sealed system; 20. small appliances - ANSWER Any person who opens an appliance for maintenance service or repair must have at least one self-contained recovery machine available at their place of business. The exceptions to this rule are persons working on; 21. MVAC-like system that holds 3 lbs of refrigerant - ANSWER What is NOT a type 1 appliance? 22. restricted to technicians who are EPA certified in refrigerant recovery - ANSWER The sale of CFC and HCFCs are; 23. products manufactured, charged and hermetically sealed in factory and having 5 lbs or less or refrigerant - ANSWER EPA definition of small appliance 24. captures refrigerant in a non-pressurized container - ANSWER The system-dependent (passive) recovery process for small appliances; 25. 75 psig - ANSWER Storage cylinder of recovered R-12 at normal room temperature in the absence of non-condensables, will be pressurized to 26. capable of recovering 80% of the refrigerant whether or not the compressor is operating or achieving a 4 inch vacuum under the conditions of ARI 740 - ANSWER All recovery devices manufactured BEFORE November 15, 1993 27. recovering 90% of the refrigerant when the compressor is operating or achieving a 4 inch vacuum under the ARI 740 - ANSWER Small Appliance recovery equipment manufactured AFTER November 15, 1993 must be certified to be capable of; 28. it is not mandatory to repair the leak but do so whenever possible - ANSWER when servicing a small appliance for a leak repair; 29. When filling a charging cylinder with a regulated refrigerant; - ANSWER The refrigerant vapor that is vented off the top of the cylinder must be recovered. 30. If after installing a fitting for the purpose of recovering the appliances refrigerant, you find that the system pressure is 0 psig; - ANSWER Recovery is not required.

Meer zien Lees minder
Instelling
EPA 608 Type 1
Vak
EPA 608 Type 1

Voorbeeld van de inhoud

EPA 608 Type 1 2026/2027 COMPLETE
QUESTIONS WITH CORRECT DETAILED
ANSWERS || GUARANTEED PASS


1. Before opening a self contained recovery machine make sure the -
ANSWER ✅ inlet valve is open, and tank does not contain excessive air
(non condensables)


2. The only way to read refrigerant pressure correctly is at - ANSWER ✅ a
stable known temperature


3. Air in refrigeration systems will cause - ANSWER ✅ higher discharge
pressures


4. When purging non-condensables abide by - ANSWER ✅ operating
instruction supplied by equipment manfactuer


5. All refrigerant recovery equipment should be check for what on a daily basis
- ANSWER ✅ oil level and leaks


6. A system dependent recovery unit has - ANSWER ✅ special charcoal
activated plastic "bag" containers


7. System dependent equipment captures refrigerant with the assistance of -
ANSWER ✅ an applicant compressor, external heat source, or vacuum
pump

, 8. A standard vacuum pump can only be used in combination with a -
ANSWER ✅ non-pressurized container


9. In order to release trapped refrigerant from the compressor oil - ANSWER
✅ heat and tap the compressor several times and/ or use a vacuum pump


10.Because appliances with non-operating compressors can not always achieve
desired evacuation rates utilizing system dependent equipment - ANSWER
✅ The EPA requires at least one self contained recovery device available at
the shop


11.The exception to the EPA required rule of a self contained device available
is technicians - ANSWER ✅ working on small appliances only


12.System dependent devices may only be used on appliances - ANSWER ✅
containing 15 lbs. of refrigerant or less.


13.When installing an access fitting onto a sealed system, - ANSWER ✅ the
fitting should be leak tested before proceeding with recovery.


14.It is generally recommended that _____ ____ type valves be used on only
copper or aluminum tubing material, these fitting tend to leak over time and
should not be left on a permanent service fixture. - ANSWER ✅ Solder-less
piercing


15.After installing a access fitting you the system pressure to be 0 PSIG -
ANSWER ✅ do not begin recovery process.

Geschreven voor

Instelling
EPA 608 Type 1
Vak
EPA 608 Type 1

Documentinformatie

Geüpload op
12 april 2026
Aantal pagina's
11
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
DrMwendwa
1.0
(1)

Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
DrMwendwa Oxford University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2
Lid sinds
3 maanden
Aantal volgers
0
Documenten
383
Laatst verkocht
2 weken geleden
EXCELLENT ACHIEVERS LIBRARY

Dr. Mwendwa Test Banks & Practice Exams Graded A+ On this page you will find the latest exams, test banks, solution manuals, exam elaborations, and other study materials. Find study notes, exam answer packs, assignment-guided solutions, and more. Study faster & better. Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied... All the best!!!!!! Your success is our priority. Let's achieve those top grades together!!!

Lees meer Lees minder
1.0

1 beoordelingen

5
0
4
0
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen