Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

EPA 608 Type 3 2026/2027 COMPLETE QUESTIONS WITH CORRECT DETAILED ANSWERS || GUARANTEED PASS

Beoordeling
-
Verkocht
-
Pagina's
18
Cijfer
A+
Geüpload op
12-04-2026
Geschreven in
2025/2026

EPA 608 Type 3 2026/2027 COMPLETE QUESTIONS WITH CORRECT DETAILED ANSWERS || GUARANTEED PASS 1. On low pressure chillers, moisture typically enters the refrigerant system through - ANSWER air leaks from areas with gaskets or fittings 2. The maximum test pressure for leak testing a low pressure centrifugal is: - ANSWER 10 psig 3. System- dependent recovery equipment CANNOT be used when: - ANSWER the appliance contains over 15 pounds of refrigerant 4. Moisture is removed a system by: - ANSWER using a filter drier 5. When a unit is opened for servicing the ______ should always be replaced - ANSWER filter drier 6. The backseating of a suction shutoff valvee will close the: - ANSWER guage port 7. When charging an R-12 refrigeration system that uses a water cooled condensor, you must first charge with vapor to a pressure of at least _____ , before switching to a liquid charging. - ANSWER 35 psig 8. A compressor heater is used to: - ANSWER reduce the amount of refrigerant in the lubricating oil 9. While R-410A is a high pressure refrigerant, it can be stored in the back of your service van as long as: - ANSWER the temperature inside the vehicle does not exceed 125 degrees F. This is the same guidance given for R-22 and other common refrigerants. 10. For what refrigerant is an equipment room refrigerant monitor required under ASHRAE standard 15? - ANSWER R-123 11. A reciprocating compressor should not be energized if the - ANSWER discharge service valve has closed 12. What factor affects the speed of evacuation? - ANSWER the size of the equipment the ambient temperature the amount of moisture in the system 13. The evacuation of a system is a method of: - ANSWER dehydration 14. When moisrture exists in an operating system which is likely to occur? - ANSWER Acid will form 15. The over-evacuation of a system: - ANSWER does not occur 16. A system is considered dehydrated when: - ANSWER the vacuum indicator shows you have reached & held the required finished vacuum 17. When evacuating a system the hoses should be: - ANSWER equal to or larger than the vacuum pump inlet connection 18. When evacuating a system the hoses should be: - ANSWER short in length & as large in diameter as possible 19. When operating refrigerant recovery or recycling equipment the following precautions should be taken - ANSWER safety glasses & gloves along with following equipment safety precautions 20. The color code for refrigerant recovery cylinders is - ANSWER yellow tops with grey bodies 21. Never use oxygen or compressed air to pressurize a sytem because: - ANSWER when mixed with compresser oil or some refrigerants it could explode 22. When using any solvent, chemical, cleaner, chemical or refrigerant you should review - ANSWER MSDS (data sheets) 23. Refrigerant vapors or mist should not be inhaled because - ANSWER they may cause heart irregularities & or unconsciousness 24. When using recovery unit the fill level of the recovery tank can be controlled by - ANSWER mechanical float switch electronic shutt-off device weight 25. what type of refrigerant is clorine free - ANSWER HFC's 26. HCFC - ANSWER R-22 R-123 R-124 27. it is necessary to place a refrigerant label on: - ANSWER a frigerant cylinder that is being returned for reclaiming 28. DOT requires youdo this when transporting cylinders - ANSWER attach DOT classification tags 29. It is illegal to - ANSWER knowingly release refrigerant during the service, maintenance, repair or disposal of appliances with the exception of de minimis releases 30. The type of oil that is most commonly used in stationary refrigertion applications with HFC-134a refrigerant is: - ANSWER ester oil 31. The high pressure guage on service manifold sets has a contiuous scale, usall calibrated to read from: - ANSWER 0-500 psi. 32. When a systemwill not hold a vacuum after it has been evauated, then: - ANSWER the system may be leaking

Meer zien Lees minder
Instelling
EPA 608 Type 3
Vak
EPA 608 Type 3

Voorbeeld van de inhoud

EPA 608 Type 3 2026/2027 COMPLETE
QUESTIONS WITH CORRECT DETAILED
ANSWERS || GUARANTEED PASS


1. On low pressure chillers, moisture typically enters the refrigerant system
through - ANSWER ✅ air leaks from areas with gaskets or fittings


2. The maximum test pressure for leak testing a low pressure centrifugal is: -
ANSWER ✅ 10 psig


3. System- dependent recovery equipment CANNOT be used when: -
ANSWER ✅ the appliance contains over 15 pounds of refrigerant


4. Moisture is removed a system by: - ANSWER ✅ using a filter drier


5. When a unit is opened for servicing the ______ should always be replaced -
ANSWER ✅ filter drier


6. The backseating of a suction shutoff valvee will close the: - ANSWER ✅
guage port


7. When charging an R-12 refrigeration system that uses a water cooled
condensor, you must first charge with vapor to a pressure of at least _____ ,
before switching to a liquid charging. - ANSWER ✅ 35 psig

,8. A compressor heater is used to: - ANSWER ✅ reduce the amount of
refrigerant in the lubricating oil


9. While R-410A is a high pressure refrigerant, it can be stored in the back of
your service van as long as: - ANSWER ✅ the temperature inside the
vehicle does not exceed 125 degrees F. This is the same guidance given for
R-22 and other common refrigerants.


10.For what refrigerant is an equipment room refrigerant monitor required
under ASHRAE standard 15? - ANSWER ✅ R-123


11.A reciprocating compressor should not be energized if the - ANSWER ✅
discharge service valve has closed


12.What factor affects the speed of evacuation? - ANSWER ✅ the size of the
equipment
the ambient temperature
the amount of moisture in the system


13.The evacuation of a system is a method of: - ANSWER ✅ dehydration


14.When moisrture exists in an operating system which is likely to occur? -
ANSWER ✅ Acid will form


15.The over-evacuation of a system: - ANSWER ✅ does not occur


16.A system is considered dehydrated when: - ANSWER ✅ the vacuum
indicator shows you have reached & held the required finished vacuum

, 17.When evacuating a system the hoses should be: - ANSWER ✅ equal to or
larger than the vacuum pump inlet connection


18.When evacuating a system the hoses should be: - ANSWER ✅ short in
length & as large in diameter as possible


19.When operating refrigerant recovery or recycling equipment the following
precautions should be taken - ANSWER ✅ safety glasses & gloves along
with following equipment safety precautions


20.The color code for refrigerant recovery cylinders is - ANSWER ✅ yellow
tops with grey bodies


21.Never use oxygen or compressed air to pressurize a sytem because: -
ANSWER ✅ when mixed with compresser oil or some refrigerants it could
explode


22.When using any solvent, chemical, cleaner, chemical or refrigerant you
should review - ANSWER ✅ MSDS (data sheets)


23.Refrigerant vapors or mist should not be inhaled because - ANSWER ✅
they may cause heart irregularities & or unconsciousness


24.When using recovery unit the fill level of the recovery tank can be controlled
by - ANSWER ✅ mechanical float switch
electronic shutt-off device
weight

Geschreven voor

Instelling
EPA 608 Type 3
Vak
EPA 608 Type 3

Documentinformatie

Geüpload op
12 april 2026
Aantal pagina's
18
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
DrMwendwa
1.0
(1)

Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
DrMwendwa Oxford University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2
Lid sinds
3 maanden
Aantal volgers
0
Documenten
383
Laatst verkocht
2 weken geleden
EXCELLENT ACHIEVERS LIBRARY

Dr. Mwendwa Test Banks & Practice Exams Graded A+ On this page you will find the latest exams, test banks, solution manuals, exam elaborations, and other study materials. Find study notes, exam answer packs, assignment-guided solutions, and more. Study faster & better. Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied... All the best!!!!!! Your success is our priority. Let's achieve those top grades together!!!

Lees meer Lees minder
1.0

1 beoordelingen

5
0
4
0
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen