AGMT Architectural Glass & Metal Technician
Certification ACTUAL EXAM QUESTIONS AND CORRECT
DETAILED ANSWERS LATEST UPDATE THIS YEAR
AGMT Architectural Glass & Metal Technician Certification Practice Exam
10-Line Exam Coverage
1. Certification Overview – ANSI-accredited credential for experienced glaziers (7,500+
hours) requiring Knowledge-Based Test (KBT) and Performance-Based Test (PBT) with
recertification every 4 years .
2. Safety & OSHA Regulations – 29 CFR 1926 (Subpart M fall protection, Subpart L
scaffolds), anchor strength 5,000 lb, PPE (cut-resistant gloves, safety glasses) .
3. Glass Types & Properties – Tempered (safety, small cubes), laminated (PVB interlayer,
holds fragments), annealed, heat-strengthened, low-E, and IGU construction .
4. Handling & Installation – Vacuum lifters and suction cups, vertical transport, setting
blocks, edge clearance for thermal movement, storage with padding and bracing .
5. Curtain Wall & Storefront Systems – Unitized vs. stick-built, pressure-equalized design,
thermal breaks, backpans, weep holes, mullion alignment .
6. Sealants & Weatherproofing – Silicone (structural glazing, UV-resistant), neutral cure,
backer rods for depth control, weep hole drainage, EPDM gaskets .
7. Codes & Standards – ASTM E1300 (glass deflection), ANSI Z97.1 (safety glazing), NFRC
(energy ratings), CPSC 16 CFR 1201 (impact) .
8. Blueprint Reading & Layout – Symbols (Ø = diameter, "T" for tempered), bite dimension,
framing square for squareness, laser level alignment .
9. Metal Technology – Aluminum alloys (6063), anodizing (electrochemical corrosion
protection), galvanic corrosion prevention, expansion anchors .
10. Quality Control & Testing – Suction cup inspection before each use, torque
specifications, sealant adhesion testing, glass deflection limits per ASTM .
, Page 2 of 95
200 MCQs with Rationales
Section 1: Certification Overview & Requirements (Q 1-15)
1. What is the AGMT certification's primary mission?
a) To train entry-level glaziers in basic safety
b) To validate experienced glaziers' fundamental knowledge, skills, and abilities
c) To replace union apprenticeship programs
d) To certify glass manufacturing processes
Correct Answer: b) To validate experienced glaziers' fundamental knowledge, skills, and
abilities
Rationale: The AGMT program is designed to provide a means to validate that a glazing
technician has the fundamental knowledge, skills, and abilities to perform work in a manner
that will minimize defects and failures .
2. How many glazing-related work hours must an AGMT candidate demonstrate before
applying?
a) 2,500 hours within 2 years
b) 5,000 hours within 3 years
c) 7,500 hours within 5 years
d) 10,000 hours within 7 years
, Page 3 of 95
Correct Answer: c) 7,500 hours within 5 years
Rationale: Eligible candidates must demonstrate at least 7,500 hours (within five years) of
glazing-related work experience and must possess OSHA-10 certification .
3. The AGMT certification is accredited by which organization?
a) OSHA (Occupational Safety and Health Administration)
b) ANSI (American National Standards Institute)
c) ASTM (American Society for Testing and Materials)
d) NFRC (National Fenestration Rating Council)
Correct Answer: b) ANSI (American National Standards Institute)
Rationale: The AGMT certification is accredited by the American National Standards Institute
(ANSI), ensuring it meets rigorous standards for personnel certification programs .
4. How often must AGMT certification be renewed?
a) Every 2 years
b) Every 4 years
c) Every 5 years
d) Lifetime certification, no renewal required
, Page 4 of 95
Correct Answer: b) Every 4 years
Rationale: AGMT certified technicians must recertify every four years, including written testing,
evidence of required work hours, and completion of continuing education .
5. Which two assessments comprise the AGMT certification process?
a) Written essay and oral interview
b) Knowledge-Based Test (KBT) and Performance-Based Test (PBT)
c) Online quiz and employer evaluation
d) Safety exam and blueprint reading test
Correct Answer: b) Knowledge-Based Test (KBT) and Performance-Based Test (PBT)
Rationale: The assessment is divided into two tests—a Knowledge-based Test (KBT) and a
Performance-based Test (PBT)—designed to evaluate a technician's fundamental knowledge,
skill, and abilities required to proficiently perform foundational or basic glazing tasks .
6. The AGMT Performance-Based Test (PBT) includes which hands-on sections?
a) Glass cutting and annealing only
b) Curtain Wall, Storefront, Sealant, Layout, and Harness Tests
c) Welding and fabrication only
d) Blueprint reading and estimating