There shall be a wall switch at each floor to control stairway lighting where the stairway
has _____ or more risers - ANSWERS-6
Flanges and lips of load-bearing cold-formed steel floor framing members shall not be
cut or ____. - ANSWERS-Notched
Gas vents over 12 inches in size shall terminate not less than _____ feet above the
highest point where they pass through the roof. - ANSWERS-2 feet
Foundations for masonry chimneys shall be constructed of concrete or solid masonry at
least _____ inches thick - ANSWERS-12 inches
Supports and foundations for the outdoor unit of a heat pump shall be raised at least
___ inches above the ground. - ANSWERS-3 inches
Attic ventilation openings shall have a least dimension of _________ inch minimum to
_________ inch maximum openings. - ANSWERS-1/16 And 1/4
All wood beams, joists, studs and other combustible material shall have a clearance of
not less than _____ inches from the front faces and sides of masonry fireplaces. -
ANSWERS-2 inches
The minimum headroom in all parts of the stairway shall not be less than _____ feet,
_____ inches - ANSWERS-6 feet, 8 inches
,A nosing not less than ____ inch but not more than ____ inches shall be provided on
stairways with solid risers. - ANSWERS-3/4 And 1 1/4
Unattached decks not exceeding _____ square feet in area, that are not more than
_____ inches above grade do not require a permit. - ANSWERS-200 sqft. And 30
inches
Gas appliance shut off valves shall be located in the same room as the appliance and
not further than _____ feet from the appliance - ANSWERS-6 feet
BTU is abbreviation for _____ _____ ______, which is the quantity of heat required to
raise the temperature of 1 pound of water 1*F - ANSWERS-British thermal unit
Stairways shall not be less than ____ inches in clear width at all points above the
permitted handrail height and below the required headroom height. - ANSWERS-36
inches
An automatic fire sprinkler system is not required when _____ or _____ are made to
existing townhouses that do not have a sprinkler system - ANSWERS-Additions and or
Alterations
Chimney shall extend at least _____ feet higher than any portion of a building within
____ feet. - ANSWERS-2 feet, 10 feet
Window wells serving emergency escape and rescue openings shall be designed for
proper ____. - ANSWERS-Drainage
Braces wall panels shall be constructed with intermittent bracing method s, or the
continuous sheathing methods. Mixing of bracing methods shall be ______. -
ANSWERS-Permitted
,Physical interconnection of smoke alarms is not required where ____ ___ alarms are
installed. - ANSWERS-Listed wireless
(All alarms must sound upon activation of one alarm).
Physical interconnection of smoke alarms is not required where ____ ___ alarms are
installed. - ANSWERS-Listed wireless
(All alarms must sound upon activation of one alarm).
A thermal barrier is not required for foam plastic insulation in an attic that is entered only
for purposes of _____ or ______. - ANSWERS-Repairs or Maintenance
ANy portion of a masonry chimney located in the interior of a building or within an
exterior wall shall have a minimum air space clearance to combustibles of _____
inches. - ANSWERS-2 inches
The provisions of Section R505 Steel Floor Framing shall control the construction of
cold-formed steel floor framing for building not greater than ____ feet in length
perpendicular to the joist span. - ANSWERS-60 feet
For rooms with sloped ceilings, at least ____ percent of the required floor area of the
room must have a ceiling height of not less than 7 feet. - ANSWERS-50%
Where raceways are installed in wet locations above grade, the interior of such
raceways shall be considered to be a ______________ location. - ANSWERS-Wet
Perforated foundation drains shall be surrounded with an approved ____ ____. -
ANSWERS-filter membrane
Chapter 11 regulates the ___________ efficiency for the design and construction of
buildings regulated by this code. - ANSWERS-Energy
, A pane of glass in a window requires safety glazing if the pane is greater than ____
square feet with a bottom edge less than ____ inches above the floor and top edge
greater than ____ inches above the floor. - ANSWERS-9 sqft., 18 inches, 36 inches
The connection between a deck ledger and a 2 inch nominal lumber band joist shall be
constructed with _____ inch lag screws or bolts with washers - ANSWERS-1/2 inch
At the intersection of asphalt shingles with a vertical sidewall, flashing shall be a
minimum of _____ inches in height and ____ inches in width. - ANSWERS-4 inches, 4
inches
The markings for identification of disconnecting means shall have the durability to
withstand the _____ involved. - ANSWERS-environment
A _____ shall be provided at the base of each waste or soil stack - ANSWERS-
Cleanout
All mechanical elements used to terminate a grounding electrode conductor or bonding
jumper to the grounding electrodes shall be __________________. - ANSWERS-
Accessible
A flight of stairs shall not have a vertical rise larger than ____ feet between floor levels
or landings. - ANSWERS-12 feet
Sauna heaters shall be equipped with a thermostat that will limit room temperature to a
maximum of ______ . - ANSWERS-194 *F
Protection of wood and wood based products from ___ shall be provided by the use of
naturally durable wood or wood that is preservative treated. - ANSWERS-Decay
In plumbing systems, supports for 1 inch copper or copper alloy tubing run horizontal
shall not be spaced more than ______ feet apart. - ANSWERS-6 feet