Compliance Inspector Certification
Exam Practice Questions And Correct
Answers (Verified Answers) Plus
Rationale 2026 Q&A| Instant Download
1. Which body primarily adopts the energy code that inspectors in
Arizona municipalities enforce?
A. International Code Council (ICC)
B. Arizona State Legislature
C. U.S. Department of Energy
D. American Society of Heating, Refrigerating and Air-Conditioning
Engineers
Rationale: The Arizona State Legislature adopts and mandates
specific energy codes that municipal compliance inspectors must
enforce.
2. The Residential Energy Code in Arizona is based on which model
code?
A. ASHRAE 90.1
B. International Energy Conservation Code (IECC)
C. National Electrical Code
, D. International Building Code
Rationale: The Residential Energy Code implemented in Arizona
municipalities is derived from the International Energy Conservation
Code.
3. What is the primary purpose of an energy compliance inspection?
A. Determine market value of a building
B. Verify that construction meets energy code requirements
C. Approve occupancy permits
D. Evaluate seismic safety
Rationale: Energy compliance inspections verify that building
construction complies with adopted energy efficiency standards.
4. Which system is used to calculate expected energy performance for
compliance?
A. LEED
B. BREEAM
C. REScheck
D. HERS
Rationale: REScheck is the compliance software approved for
demonstrating residential energy code compliance.
5. For commercial buildings, which software is commonly used to
demonstrate energy code compliance?
A. ENERGY STAR Portfolio Manager
B. COMcheck
C. RETScreen
D. Green Globes
Rationale: COMcheck is the compliance demonstration tool approved
for commercial energy code compliance.
6. What is the minimum insulation requirement for ceilings in Arizona’s
climate zones under the IECC?
, A. R-13
B. R-38
C. R-19
D. R-30
Rationale: In many Arizona climate zones, the IECC requires a
minimum ceiling insulation value of R-38 for compliance.
7. An inspector finds that fenestration U-factor is higher than allowed
by the code. This is considered a violation because:
A. It improves ventilation
B. Reduces construction cost
C. It decreases thermal performance
D. Enhances daylighting
Rationale: Higher U-factor means worse thermal performance,
violating energy conservation standards.
8. Air leakage testing of a building envelope is also known as:
A. Smoke test
B. Blower door test
C. Duct pressurization test
D. Infrared scan
Rationale: Blower door testing measures building envelope
airtightness as required by the code.
9. Which term describes the rate of heat transfer through a material?
A. BTU
B. U-factor
C. ACH
D. Lumen
Rationale: U-factor quantifies the rate of heat transfer and is critical
in energy code compliance.