Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

P-99 / Low PSI oIL Burner oPerator eXaM wItH CorreCt aCtuaL QueStIonS anD CorreCtLY weLL DeFIneD anSwerS LateSt aLreaDY GraDeD a+

Beoordeling
-
Verkocht
-
Pagina's
12
Cijfer
A+
Geüpload op
13-04-2026
Geschreven in
2025/2026

P-99 / Low PSI oIL Burner oPerator eXaM wItH CorreCt aCtuaL QueStIonS anD CorreCtLY weLL DeFIneD anSwerS LateSt aLreaDY GraDeD a+

Instelling
P-99 / Low PSI OIL Burner OPerator
Vak
P-99 / Low PSI oIL Burner oPerator

Voorbeeld van de inhoud

P-99 / Low PSI oIL Burner oPerator eXaM wItH CorreCt aCtuaL
QueStIonS anD CorreCtLY weLL DeFIneD anSwerS LateSt aLreaDY
GraDeD a+




All heating, combustion, and cooking equipment shall be provided with insulation or the building
construction shall be fire protected, so that during operation the surface of combustible
construction materials will not be raised to a temperature higher than ____. - anSwer-170 ̊ F



Acceptance tests: Boilers shall not be placed in operation upon completion of construction until
they have been ____ and an equipment use permit has been issued by the commissioner. -
anSwer-Inspected and tested.



Periodic boiler inspections: All boilers shall be inspected at least ____ including chimney
connections. - anSwer-Once a year.



Owner's annual statement: The owner of each boiler that is subject to periodic inspections shall
file an annual ____ with the commissioner, specifying the location of each boiler and
arrangement for inspection. - anSwer-Written statement.



What three things must be tested for any fuel burning and storage installation before the system
can be operated? - anSwer-(1) Tightness of liquid fuel piping.



(2) Tightness of fuel oil storage tanks.



(3) Tightness of gas distribution piping.



What are instruction cards for oil burning systems? - anSwer-Cards giving complete instructions
for care and operation that are permanently located near the equipment.

, Every oil burning installation that is not fully automatic or requires preheating shall be operated
by, or under, the direct supervision of a person holding a ____ issued by the fire commissioner. -
anSwer-COF



After any fuel burning equipment repair for which a licensed operator is required, such operator
shall also check the repairs and be ____ while the equipment is started. - anSwer-Present.



What is abatement of air contaminants? - anSwer-Compliance with the air pollution control
code.



What are the 3 equipment classifications and their temperatures for the products of combustion
at the point of leaving the equipment? - anSwer-(1) Low Temp: 600° F or less.



(2) Medium Temp: 600° - 1000° F.



(3) High Temp: 1000° or greater.



Ventilation shall be capable of providing at least ____ CFM of air for each gallon of oil per hour
required to fire the equipment to gross output. - anSwer-36



What is fuel-oil? - anSwer-Hydrocarbon oils with a flashpoint not lower than 100 ̊F.



The use of crankcase refuse oil as fuel-oil is ____. - anSwer-Prohibited.



Overflow pipes shall not be smaller in size than the ____ pipe. - anSwer-Supply.



Oil is heated in storage tanks by coils using which three possible methods? - anSwer-(1) Low
pressure hot water.



(2) Steam

Geschreven voor

Instelling
P-99 / Low PSI oIL Burner oPerator
Vak
P-99 / Low PSI oIL Burner oPerator

Documentinformatie

Geüpload op
13 april 2026
Aantal pagina's
12
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$18.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
DoctorDee Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
24
Lid sinds
2 jaar
Aantal volgers
7
Documenten
4421
Laatst verkocht
11 uur geleden
Hi wayne1111

3.5

6 beoordelingen

5
3
4
0
3
1
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen