BOARD RULES TEST 2026 COMPLETE
QUESTIONS AND VERIFIED
ANSWERS
◉ Can a licensed Journeyman perform a cleaning on a wood/oil
combination unit without direct supervision? Answer: If they have an
apprentice solid fuel license MFC 3.2.7
◉ A graduate of an 160 hour Maine fuel board approved course on oil
burning equipment may set for the journeyman exam when? Answer:
Upon successful completion of the requisite education, prior to
completing the apprenticeship
◉ The Maine fuel board adopts NFPA 31 and NFPA 211, which
edition? Answer: NFPA 31 2011 edition and NFPA 211 2013 edition.
MFC 6.1.2 and 6.1.13
◉ What are the two chapters and sections of NFPA 31 that Maine does
not adopt? Answer: Chapter 7 section 7.12 and Chapter 7 section 7.3.1
MFC 6.2.1
◉ What does Maine fuel board say about inspecting chimneys as
required by NFPA 211 chapter 14?` Answer: The Maine fuel board does
not adopt chapter 14 of NFPA 211. MFC 6.2.6.4.3
, ◉ All work must be conducted, installed and completed in a ______?
Answer: Neat and professional manner reflecting a minimum level of
workmanship. MFC 8.2
◉ When performing any service work on a customer's heating system,
the licensee must notify the homeowner of? Answer: Any code
violations and make recommendations to address them. MFC 8.4.2
◉ When performing an annual tune-up on a heating system a
combustion efficiency test must be? Answer: Conducted and a copy of
the results must be posted on site. MFC 8.4.3
◉ When installing a furnace, direct fired water heater or boiler what
must be done prior to placing it in service? Answer: The total
installation must be brought into compliance with the requirements of
NFPA 31 and all other rules of the Maine fuel board. MFC 8.5.1
◉ When installing a new oil burner the ____ must be brought into
compliance with the rules of the board before ______? Answer: Wiring;
the unit is fired. MFC 8.5.2
◉ What wiring update must be included when a new oil burner is
installed? Answer: Proper rated fuse or breaker, proper rated wire,
properly installed and located emergency, thermal and service switches
and properly installed and located low water cutoff. MFC 8.5.2