According to the IBC, the "blank" is owner or owners agent. 2009 IBC Section 1704.1
to hire the special inspector.
According to the IBC, the "blank" is code official. 2009 IBC, Section 1704.1
the responsible for the approval of a
person's qualifications to act as a
special inspector.
According to the IBC, discrepancy final report. 2009 IBC, Section1704.1.2
corrections are made known to the
building official by:
When is the code official to be made If it is not corrected by the contractor. 2009 IBC,
aware of a discrepancy found during Section 1704.1.2
a special inspection?
According to the Model Program for In a written report - Section II B 4 - Model
Special Inspection, the special Programs
inspector is to document work that is
nonconforming:
https://quizlet.com/1168610498/icc-bolting-exam-updated-2026-questions-answers-with-100-correct-answers-graded-a-guaranteed-success-flash-car… 1/25
,4/16/26, 6:28 AM ICC Bolting EXAM (updated 2026) Questions & Answers | With 100% Correct Answers graded A+ Guaranteed Success!! Flashcard…
According to the Model Program for After each inspection visit - Section II B 5 - Model
Special Inspection, the special Programs
inspector is to prepare written report
of inspection:
According to the Model Program for Description of discussions with the contractor -
Special Inspection, which of the Section B 5 - Model Programs
following items does not need to be
included in each inspection report?
According to the Specification for 1/16 inch - Specification for Structural Joints Table
Structural Joints using high strength 3.1
bolts, the nominal diameter of
standard bolt holes shall be how
much larger than the nominal bolt
diameter?
Discrepancies in the work shall be the contractor - 2009 IBC, Section 1704.1.2.
brought to the immediate attention
of the "blank" for corrective action.
The special inspector shall furnish Building Official and Registered Design
inspection reports to the "blank" and professional
to the "blank"?
The special inspector shall provide Single-pass fillet welds greater than 5/16 inch in
continuos inspection of: size - 2099 IBC, Table 1704.3, Item 5.3
The special inspections required by Approved fabricator - 2009 IBC, Section 1704.2.2
this code are not required where the
work is done on the premise of a?
https://quizlet.com/1168610498/icc-bolting-exam-updated-2026-questions-answers-with-100-correct-answers-graded-a-guaranteed-success-flash-car… 2/25
, 4/16/26, 6:28 AM ICC Bolting EXAM (updated 2026) Questions & Answers | With 100% Correct Answers graded A+ Guaranteed Success!! Flashcard…
The special inspection of the steel heating operations - 2009 IBC, Section 1704.3,
fabrication process shall not be Exceptions # 1
required where the fabricator does
not perform any?
According to the Specifications for A568 - Section A31, Specifications for Structural
Structural Steel Buildings, ASTM Steel Buildings
Standard "blank" is to be used for the
material test for steel sheets.
According to the Specifications for Fabricator or Testing Laboratory - Section A31,
Structural Steel Buildings, the "blank" Specifications for Structural Steel Buildings.
conducts the material tests for
identification of the structural steel.
According to the Specifications for Unimportant members, where their physical
Structural Steel Buildings, which of properties and weldability would not affect the
the following steel members are structure strength - Section A31b, Specifications for
allowed to be unidentified steel? Structural Steel Buildings
According to the Code of Standard It is marked by the supplier - Section 5.1.1, Code of
Practice for Steel Buildings and Standard Practice for Steel Buildings and Bridges
Bridges, how is steel of special
material to be identified?
According to the Code of Standard Certified mill test reports - Section 5.2.2 - Code of
Practice for Steel Buildings and Standard Practice for Steel Buildings and Bridges
Bridges, how are fabricators stock
steel material identified?
According to the Specification for A53 - Section A31a - Specification for Structural
Structural Steel Buildings, what ASTM Steel Buildings
Standard would apply to a sample
for structural steel pipe?
https://quizlet.com/1168610498/icc-bolting-exam-updated-2026-questions-answers-with-100-correct-answers-graded-a-guaranteed-success-flash-car… 3/25